The measured responses of the eight filters are shown in Figure 78 and Figure 79 (note the change of horizontal
scale between the two figures).
Six additional filters are available allowing for a total of 14. The optional filters are 70 kHz, 1.4 MHz, 3 MHz, 6
MHz, 14 MHz, and 28 MHz. The measured responses of the optional filters are shown in Figure 80 and Figure 81.
Contact Quasonix for information about the optional filters.