Rack-Mount RDMS
TM
Telemetry Receiver
57
Quasonix, Inc.
4.1.5.10.1 Synchronize Measured Bit Rate
Synchronize Measured Bit Rate sets the receiver’s commanded bit rate to the value it is currently measuring on the
input signal. The purpose of this process is to eliminate unintended bit rate offset error so that the receiver can make
full use of its bit synchronizer tracking range, or optionally reduce its tracking range. For the receiver to have an
accurate measurement, however, the input signal must be close enough to the previously commanded bit rate to be
within the current bit synchronizer lock range and actually be locked.
The Sync Measured Bit Rate option is located on the Advanced Menu, as shown in Figure 102. This option may be
set using this front panel menu or via the Remote RDMS™ Client, Advanced Settings window (refer to section
4.2.5.1).
Figure 102: Advanced Menu, Sync Measured Bit Rate Selection
To apply a new measured bit rate, use the value displayed in the entry screen or, type a number using the numeric
buttons. The right arrow button is used to advance to the next cursor position. Allowable value ranges vary
depending on the waveform mode in use. Press the
Enter
button to accept changes. Repeat this step to apply a
different measured bit rate.
A signal lock must be present for this entry screen to display. If there is no signal lock, the message shown in Figure
104 displays.
Figure 103: Advanced Menu, Measured Bitrate Entry Screen