Rack-Mount RDMS
TM
Telemetry Receiver
131
Quasonix, Inc.
Note:
Access to this serial control interface is provided primarily for debugging purposes. Unlike the standard front
panel and remote client interfaces, the serial control interface within the Advanced Terminal window is not
safeguarded from accidental or improper changes to the receiver’s configuration.
It is
strongly
recommended that users contact Quasonix Technical Support (Tel: 513-942-1287) prior to using the
Advanced Terminal serial control interface.
Changes made within the serial command interface of the Advanced Terminal window are not automatically filtered
into the Basic Settings window. However, the RRC is able to detect when serial commands are given, at which time
the green Refresh Settings screen button begin to flash in order to prompt the user.
Figure 239: Advanced Terminal Window with User Message
All commands are one or two alphabetic characters, followed by 0, 1, or 2 arguments. If the command is issued with
arguments, there must be a space after the alphabetic characters. The commands are not case sensitive.
All commands generate a response of one or more lines. The length of the response depends on the verbosity level
(set by the VL command – this is an advanced command). The last response line is always the currently selected
mode (PCMFM, SOQPSK, CPM, or PSK), followed by the character “+” or “>”, depending on the version of the
firmware. This prompt signifies that the RDMS™ is ready to accept new characters.
A complete list of available serial commands can be found in section 4.3.2.