Bit Error Rate Tester | BERT 1005
Quantifi Photonics Ltd.
Version
2.04
58
Command
*OPC?
Syntax
*OPC?
Description
Query the Operation Complete Status
Parameters
No parameters
Response
1
is returned if all the modules installed in the chassis are ready to execute commands
0
is returned if any module in the chassis has a command to execute in the input queue
Example
*OPC? -> 1
Command
*OPT?
Syntax
*OPT?
Description
Query the modules managed by the CohesionSCPI service
Parameters
No parameters
Response
Response will be a comma separated string of the installed modules in the chassis
Example
*OPT? -> ,LaserPXIe-1002-2-FA,SwitchPXIe-1003-1-FC,,VOAPXIe-1001-2-
FA,,,,O2EPXIe-1001-1-FC,,,,,,,,,
Specific command summary
Slot commands
Description
:SLOT<n>
:OPC?
- Query the status of the Operation Complete bit
:TeST?
- Perform a self-test of the module
:OPTions?
- Query the modules installed on the slot
:IDN?
- Query the Identifier for the slot; returns the manufacturer, part
number, serial number, hardware and firmware versions
:GRouP?
:PPG?
- Query the PPG channels within the specified group
:ED?
- Query the ED channels within the specified group
:TEMPerature?
- Query the temperature of all groups of channels
Configuration commands
Description
:CALCulate<n>
:DATA<m>
:EALarm?
- Query the ED error measurement
:ELAPsed?
- Query the running time for the ED measurement
:EDIagram?
- Query the eye scan measurement data
:STATus?
- Query the eye scan measurement status
:BATHtub?
- Query the BER values from the bathtub measurement
:STATus?
- Query the status of the bathtub measurement
:ELAPsed?
- Query the elapsed time of the bathtub measurement and the time to
next point
:Q?
- Query the Q values from the bathtub measurement
:BERFloor?
- Query the BER floor value from the bathtub measurement
:CENTer?
- Query the center of the eye from the bathtub measurement
:JITTer?
- Query the Jitter values from the bathtub measurement
:OUTPut<n>
:CLOCk
:VCOLock?
- Query the stability of the clock synthesizer
:DIVIde?
- Query the clock synthesizer divide ratio
:DIVIde
- Set the clock synthesizer divide ratio
:FREQuency
:ARBitrary?
- Query the current synthesizer frequency arbitrary settings
:ARBitrary
- Set the current synthesizer frequency to an arbitrary value within the
valid operating range
:STanDard?
- Query the current synthesizer frequency standard settings
:STanDard
- Set the current synthesizer frequency to a standard value
Содержание BERT 1005 Series
Страница 1: ......
Страница 6: ...Bit Error Rate Tester BERT 1005 Quantifi Photonics Ltd Version 2 04 6 Service and repairs 93 ...
Страница 94: ...2 04 ...