Quadra-Fire • SAPH-MBK-IPI, SAPH-D-PMH-IPI, SAPH-D-MBK-IPI, SAPH-D-CSB-IPI Installation Manual • 2343-980_R8 • 11/14
32
6
Appliance Preparation
A. Top to Rear Vent Conversion
this model comes from the factory set up for a top vented
application. to vent this model from the rear, follow the
conversion instructions below. If venting off the top, no
further preparation is needed. Proceed to next section.
See Service Parts list in owner’s Manual for Kit information.
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during
installation. Sheet metal edges are sharp.
Included in Kit:
Rear vent grille, Ng orifice (#46), lP orifice
(#55)
Tools Required:
Power drill, 1/4 in. hex driver bit, 3/8 in. open
end wrench, high temperature sealant (if required)
Note:
tIaRaI-IPI unit is shown in the photos and drawings
in this instruction. Instructions apply to both tIaRaI-IPI and
SaPh-IPI units.
Figure 4
4. locate the knock out on rear of appliance. Break the seal
on the knock out and discard the knock out.
Figure 1
1. Remove top grille, as highlighted.
Figure 2
2. Remove vent pipe adapter and gasket by removing 4
screws. Save the screws. (If gasket breaks, apply high-
temp sealant to bottom of adapter before installing as
shown in Figure 8.) 3. Remove the inner pipe adapter
shown in Figure 3 by removing six screws. Remove
gasket and discard. Replace six screws into holes and
tighten.
KNOCKOUT
REAR PLATE
AND GASKET
Figure 5
Figure 3.
INNER PIPE ADAPTER
REMOVE
SCREwS (6)