background image

September 26, 2016 

 

 

 

 

           7037-172 

 

 

         

                 3

4300 Wood Appliance Series ACC

The Quadra-Fire 4300 Series Wood Appliance meets the 

U.S. Environmental Protection Agency’s crib wood emission  

limits for wood appliances sold after May 15, 2015. 

A.  Appliance Certification

B.  BTU & Efficiency Specifications

NOTE:  Hearth & Home Technologies, manufacturer of 

this appliance, reserves the right to alter its products, their 

specifications and/or price without notice.

C.  Mobile Home Approved

 • 

This appliance is approved for mobile home installa-

tions; when not installed in a sleeping room and when 

an outside combustion air inlet is provided.

 • 

The structural integrity of the mobile home floor, ceil

-

ing, and walls must be maintained. 

 • 

The appliance must be properly grounded to the frame 

of the mobile home with #8 copper ground wire

 • 

Outside Air Kit, part OAK-ACC must be installed in a 

mobile home installation.

Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. 

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

Hearth & Home Technologies WILL NOT warranty appli

-

ances that exhibit evidence of over-firing.  Evidence of 

over-firing includes, but is not limited to:

  •  Warped air tube

  •  Deteriorated refractory brick retainers

  •  Deteriorated baffle and other interior components

D.  Glass Specifications

This appliance is equipped with 5mm ceramic glass.  

Replace glass only with 5mm ceramic glass.  Please con-

tact your dealer for replacement glass.

NOTE:  This installation must conform with local codes. 

In the absence of local codes you must comply with the 

UL1482-07, (UM) 84-HUD and NFPA211 in the U.S.A. and 

the ULC S627-00 and CAN/CSA-B365 Installation Codes 

in Canada.

F. Combustible Materials

Material made of/or surfaced with any of the following ma

-

terials: 

 

- Wood  

 

- Compressed Paper

 

- Plant Fibers   

- Plastic

 

- Plywood/OSB   

- Sheet Rock (drywall)

Any material that can ignite and burn: flame proofed or not, 

plastered or non-plastered. 

E. Non-Combustible Materials

Material which will not ignite and burn, composed of any 

combination of the following: 

 - 

Steel 

  - 

Plaster

 - 

Brick 

  - 

Iron

 - 

Concrete 

 - 

Tile

 - 

Glass 

  - 

Slate

Materials reported as passing 

ASTM E 136, Standard 

Test Method for Behavior of Metals, in a Vertical Tube 

Furnace of 750° C. 

Model:

4300 Millennium  & Step Top (ACC) 

Uni-Body

Laboratory:

OMNI Test Laboratories, Inc.

Report No & Date:

061-S-67-6

Type:

Listed Room Heater, Solid Fuel Type

Standard:

UL1482 and ULC S627-00 and (UM) 

84-HUD, Mobile Home Approved.

EPA Certification #:

656

EPA Certified Emissions:

1.00 grams per hour

*LHV Tested Efficiency:

80.2 %

**HHV Tested Efficiency:

74.2 %

***EPA BTU Output: 11,800 to 38,300 / hr.

****Peak BTU/Hour Output:

63,700

Vent Size:

6 inches

Firebox Size:

2.30 cubic feet

Recommended Wood Length:

18 inches

Fuel Orientation:

Front-to-Back

Fuel Seasoned Cord Wood

*Weighted  average  LHV  (Low  Heating  Value)  efficiency  using 

Douglas Fir dimensional lumber and data collected during EPA 

emission test. 

**

Weighted average HHV (High Heating Value) efficiency using 

Douglas Fir dimensional lumber and data collected during EPA 

emission test. 

***

A range of BTU outputs based on EPA Default Efficiency and 

the burn rates from the low and high EPA tests, using Douglas 

Fir dimensional lumber.

****

A peak BTU out of the appliance calculated using the max-

imum first hour burn rate from the High EPA Test and the BTU 

content of cord wood (8600) times the efficiency.

Important Safety Information

Содержание 43M-ACC-MBK

Страница 1: ... over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause a house fire WARNING WARNING Fire Risk For use with solid wood fuel only Other fuels may over fire and generate poisonous gases i e carbon monoxide Installation Manual Installation Appliance Set Up INS...

Страница 2: ...Specifications 3 E Non Combustible Materials 3 F Combustible Materials 3 2 Getting Started 4 A Design and Installation Considerations 4 B Fire Safety 4 C Negative Pressure 5 D Tools And Supplies Needed 5 E Inspect Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Hearth Protection Requirements 10 C Clearances to Combustibles 12 4 Chimney Syst...

Страница 3: ...th the UL1482 07 UM 84 HUD and NFPA211 in the U S A and the ULC S627 00 and CAN CSA B365 Installation Codes in Canada F Combustible Materials Material made of or surfaced with any of the following ma terials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non plastered E Non Combustible Materials Mate...

Страница 4: ...ation Installation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building fire officials or authori ties having jurisdiction about restrictions installation inspection and permits CAUTION NOTICE HEARTH HOME TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR THE IMPROPER PERFORMANCE OF THE APPLIANCE SYSTEM CAUSED BY Inadequate draft due to environm...

Страница 5: ...ll combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed Basemen...

Страница 6: ...given to the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contained in this installation manual Customer __________________________________________________________________________ Date Installed __________________________________________...

Страница 7: ...6 in 406mm 10 15 16 in 278mm 19 3 4 in 502mm C L 3 7 16 87mm 4 1 2 in 108mm Outside Air Connection C L Figure 7 1 Front View Figure 7 2 Side View 14 15 16 in 373mm 26 1 4 in 667mm 9 15 16 in 237mm 13 1 8 in 333mm 30 7 16 in 773mm 15 1 16 in 383mm 10 15 16 in 271mm 19 1 16 in 484mm C L NOTE Flue Collar size is 6 inch 152mm diameter ID 4300 Millennium Pedestal Model ...

Страница 8: ...5 1 16 636mm 10 15 16 278mm 14 15 16 379mm 19 1 16 484mm 15 1 16 383mm Figure 8 3 Front View 4300 Step Top Q Anne Leg Model Figure 8 2 Side View Figure 8 4 Side View A Appliance Dimensions continued NOTE Flue Collar size is 6 inch 152mm diameter ID 6 11 16 170mm 23 1 8 587mm 28 11 16 729mm 26 5 16 668mm 15 5 8 397mm 16 406mm 20 3 4 527mm 11 1 2 292mm 4 1 2 108mm Outside Air Connection ...

Страница 9: ...4300 Wood Appliance Series ACC Figure 9 2 Side View Figure 9 1 Front View 4300 Step Top Traditional Leg Model 33 15 16 862 23 7 16 595 25 15 16 659 A Appliance Dimensions continued NOTE Flue Collar size is 6 inch 152mm diameter ID ...

Страница 10: ...iance In Canada similar floor protection must be provided 18 inches 457mm in front and 8 inches 203mm from the sides and rear of the appliance Figure 10 2 See exception EXCEPTION Non combustible floor protector must extend beneath the flue pipe when installed with horizontal venting and extend 2 inches 51mm beyond each side See Figure 10 2 WARNING Fire Risk Hearth pads must be installed exactly as...

Страница 11: ...1334mm 52 1 2 in minimum 1066mm 42 in minimum Must extend 2 in 51mm beyond each side of pipe shaded area Figure 11 3 Figure 11 1 Figure 11 2 Step Top Uni Body Model 49 in 1245mm 5 5 1 2 i n 1 4 1 0 m m 2 7 3 8 i n 6 9 6 m m 29 1 2 in 750mm USA USA USA CANADA Corner hearth pad dimensions with single wall and double wall pipe 1245mm 1 4 5 9 m m 7 0 6 m m 782mm CANADA Figure 11 4 ...

Страница 12: ... 53 1 2 1359 12 305 STEP TOP 10 1 2 267 3 3 4 95 25 635 11 3 4 298 2 51 15 381 49 1 2 1283 5 127 INSTALLATION 90 DEGREE ELBOW OFF TOP OF STOVE THROUGH BACKWALL DOUBLE WALL PIPE MILLENNIUM 11 1 2 292 6 152 27 1 2 699 15 381 10 254 20 1 2 521 53 1 2 1359 N A STEP TOP 10 1 2 267 4 102 22 559 9 229 2 51 15 381 49 1 2 1283 N A INSTALLATION ALCOVE DOUBLE WALL PIPE MILLENNIUM 16 406 10 254 27 686 14 1 2 ...

Страница 13: ...gh the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures uneven r...

Страница 14: ...structions for clearance securing flashing and terminating the chimney Fig 14 1 14 2 Must have an approved and Listed cap Must not be located where it will become plugged by snow or other material Must terminate at least 3 feet 91cm above the roof and at least 2 feet 61cm above any portion of the roof within 10 feet 305cm Must be located away from trees or other structures NOTICE Chimney performan...

Страница 15: ...00o F or ULC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installation D Chimney Height Rise and Run This product was designed for and tested on a 6 inch 152mm chimney 14 to 16 feet 420 480cm high includes appliance height measured from the base of the appliance...

Страница 16: ...imum recommended by chimney connector manu facturer Figure 16 2 Instructions 1 Open inside wall at proper height for the chimney con nector to entry the masonry chimney Figure 16 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equiva lent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm outside dimension frame from 2 x...

Страница 17: ...FPA 211 Wall Spacer Wall Band Trim Collar Chimney Connector 1 inch 25mm Air Space to Chimney Section Min Clearance 2 inch 51mm Min Chimney Clearance to Wall Spacer and Combustibles 2 inch 51mm Chimney Section Figure 17 2 Solid Pack Chimney with Metal Supports as a Thimble Cont d G Installing Chimney Components Chimney Connector Single wall connector or appliance pipe This must be at least 24 gauge...

Страница 18: ...9 Install ARS latch by sliding latch assembly over 2 threaded studs protruding from the bottom on the left hand side of the appliance Secure by using two nuts use 7 16 socket wrench Figure 19 1 on page 19 10 Add knob to handle rod Figure 19 2 on page 19 11 Using two bolts and two flange nuts to secure ARS chan nel using 3 8 open end wrench and 7 16 socket wrench Figure 19 3 on page 19 CHECK GASKET...

Страница 19: ... 2 Install the ash drawer to pedestal base 3 Install ARS access cover inside of ARS Channel that is located inside the firebox Figure 20 2 on page 20 NOTE If installing a floor installation of an outside air kit on a Step Top model with a pedestal assembly you must attach the enclosed cover plate with 4 screw to the back of the stove Other wise you may discard this piece Figure 20 3 on page 20 CHE...

Страница 20: ...side 2 Remove the 2 bricks in the front most part of the firebox Figure 18 1 on page 18 3 Lay appliance on its back on a protective pad or pallet Figure 18 2 on page 18 4 Remove heat shield by loosening the four bolts using 3 8 open end wrench Figure 18 2 on page 18 5 Remove 8 nuts that hold the cover plate on using a 7 16 socket wrench discard cover plate Figure 18 2 on page 18 CHECK GASKET Verif...

Страница 21: ... phillips head screwdriver Start bottom two bolts through ash drawer leg brackets and into the bottom of the appliance Figure 21 1 Align top holes and repeat secure all four bolts 4 Install legs onto leg brackets making sure the legs are up against the bracket and secure with bolts and washers using a 3 8 open end wrench Figure 21 2 5 Install leveling bolts into 2 legs these leveling legs should b...

Страница 22: ...is a right and a left of the leg brackets Figure 22 1 5 Install six screws to the bottom of the leg brackets Figure 22 1 6 Attach legs onto leg brackets and secure with bolts and wash ers 7 Carefully stand stove up and place in desired location 8 Thread allen bolts through nuts until flush Figure 22 2 9 Slide allen bolt nut assemblies into slots of two of the legs with the nuts on the bottom Figur...

Страница 23: ...ead screw driver Silicone sealant Drills and saws necessary for cutting holes through the wall or flooring in your home Installation Instructions 1 Remove all materials from packing box 2 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly connect outside air to appliance intake ...

Страница 24: ...r should blow gently but should not stop G Blower Optional Tools Required 2 Phillips head screwdriver 1 Locate bolts supplied with the blower 2 Align holes in mounting flange of blower with bolt holes in appliance Blower should be positioned at bottom of rear outer skin as shown in Figure 24 1 3 Re insert and tighten bolts securing blower onto outer wall of appliance 4 Place the bracket containing...

Страница 25: ...pliance must be connected to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use silicone to create an effective vapor bar...

Страница 26: ...26 7037 172 September 26 2016 4300 Wood Appliance Series ACC Date of Service Performed By Description of Service A Service Maintenance Log 7 Reference Materials ...

Страница 27: ...of 10 832 0860 Y Washer Sae 3 8 Pkg of 3 ea 832 0990 Y Washer 1 4 Sae Pkg of 24 28758 24 Y Service Parts R 43ST ACC B Beginning Manufacturing Date Sept 2016 Ending Manufacturing Date Active IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not sell directly to consumers Provide model number and serial number when requesting ser...

Страница 28: ...peration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pe...