H.  Adjusting The Blower Speed Control 

The blower speed control for this unit is adjusted at the factory, 

and normally does not require further adjustment.  
1.  With the appliance plugged in, turn the speed control 

knob to slow (full clockwise).

2.  With a small screwdriver, adjust the blower speed by 

turning the adjustment mechanism through the hole on 

the side of the speed control.

3.  Adjust the speed so the blower runs slowly, but does 

not stop.  Turn clockwise to slow the blower and 

counterclockwise to increase the speed.

NOTE:

  When the speed control is turned clockwise, it will 

click on to high speed.  Continue to turn the speed control 

clockwise to decrease the speed.  At full clockwise, the blower 

should blow gently, but should not stop.

G.  Blower (Optional)

Tools Required:

  #2 Phillips head screwdriver

1. Locate bolts supplied with the blower.

2. Align holes in mounting flange of blower with bolt holes in 

appliance. Blower should be positioned at bottom of rear 

outer skin as shown in 

Figure 24.1

3. Re-insert and tighten bolts, securing blower onto outer 

wall of appliance.

4. Place the bracket containing the snap disc and magnet 

under the bottom left rear corner.  

 See 

Owner’s Manual

 for detailed operating instructions 

for the blower and snap disc.

Shock Risk

.

•  Do NOT remove grounding prong from plug.

•  Route cord away from appliance.
• 

Do NOT route cord under or in front of appliance.

•  Plug directly into properly grounded 3 prong receptacle.

CAUTION

Figure 24.1

Snap Disc 

Bracket 

with 

Magnet

Secure wires 

with wire tie

MANUAL

FAN

AUTO

LOW

HIGH

OFF

MANUAL: 

Over-rides 

the Snap 

Disc

AUTO: Fan 

will turn 

ON/OFF 

Automatically 

by the Snap 

Disc

Controls 

the Fan 

Speed

Содержание 43M-ACC-MBK

Страница 1: ... over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause a house fire WARNING WARNING Fire Risk For use with solid wood fuel only Other fuels may over fire and generate poisonous gases i e carbon monoxide Installation Manual Installation Appliance Set Up INS...

Страница 2: ...Specifications 3 E Non Combustible Materials 3 F Combustible Materials 3 2 Getting Started 4 A Design and Installation Considerations 4 B Fire Safety 4 C Negative Pressure 5 D Tools And Supplies Needed 5 E Inspect Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Hearth Protection Requirements 10 C Clearances to Combustibles 12 4 Chimney Syst...

Страница 3: ...th the UL1482 07 UM 84 HUD and NFPA211 in the U S A and the ULC S627 00 and CAN CSA B365 Installation Codes in Canada F Combustible Materials Material made of or surfaced with any of the following ma terials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non plastered E Non Combustible Materials Mate...

Страница 4: ...ation Installation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building fire officials or authori ties having jurisdiction about restrictions installation inspection and permits CAUTION NOTICE HEARTH HOME TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR THE IMPROPER PERFORMANCE OF THE APPLIANCE SYSTEM CAUSED BY Inadequate draft due to environm...

Страница 5: ...ll combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed Basemen...

Страница 6: ...given to the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contained in this installation manual Customer __________________________________________________________________________ Date Installed __________________________________________...

Страница 7: ...6 in 406mm 10 15 16 in 278mm 19 3 4 in 502mm C L 3 7 16 87mm 4 1 2 in 108mm Outside Air Connection C L Figure 7 1 Front View Figure 7 2 Side View 14 15 16 in 373mm 26 1 4 in 667mm 9 15 16 in 237mm 13 1 8 in 333mm 30 7 16 in 773mm 15 1 16 in 383mm 10 15 16 in 271mm 19 1 16 in 484mm C L NOTE Flue Collar size is 6 inch 152mm diameter ID 4300 Millennium Pedestal Model ...

Страница 8: ...5 1 16 636mm 10 15 16 278mm 14 15 16 379mm 19 1 16 484mm 15 1 16 383mm Figure 8 3 Front View 4300 Step Top Q Anne Leg Model Figure 8 2 Side View Figure 8 4 Side View A Appliance Dimensions continued NOTE Flue Collar size is 6 inch 152mm diameter ID 6 11 16 170mm 23 1 8 587mm 28 11 16 729mm 26 5 16 668mm 15 5 8 397mm 16 406mm 20 3 4 527mm 11 1 2 292mm 4 1 2 108mm Outside Air Connection ...

Страница 9: ...4300 Wood Appliance Series ACC Figure 9 2 Side View Figure 9 1 Front View 4300 Step Top Traditional Leg Model 33 15 16 862 23 7 16 595 25 15 16 659 A Appliance Dimensions continued NOTE Flue Collar size is 6 inch 152mm diameter ID ...

Страница 10: ...iance In Canada similar floor protection must be provided 18 inches 457mm in front and 8 inches 203mm from the sides and rear of the appliance Figure 10 2 See exception EXCEPTION Non combustible floor protector must extend beneath the flue pipe when installed with horizontal venting and extend 2 inches 51mm beyond each side See Figure 10 2 WARNING Fire Risk Hearth pads must be installed exactly as...

Страница 11: ...1334mm 52 1 2 in minimum 1066mm 42 in minimum Must extend 2 in 51mm beyond each side of pipe shaded area Figure 11 3 Figure 11 1 Figure 11 2 Step Top Uni Body Model 49 in 1245mm 5 5 1 2 i n 1 4 1 0 m m 2 7 3 8 i n 6 9 6 m m 29 1 2 in 750mm USA USA USA CANADA Corner hearth pad dimensions with single wall and double wall pipe 1245mm 1 4 5 9 m m 7 0 6 m m 782mm CANADA Figure 11 4 ...

Страница 12: ... 53 1 2 1359 12 305 STEP TOP 10 1 2 267 3 3 4 95 25 635 11 3 4 298 2 51 15 381 49 1 2 1283 5 127 INSTALLATION 90 DEGREE ELBOW OFF TOP OF STOVE THROUGH BACKWALL DOUBLE WALL PIPE MILLENNIUM 11 1 2 292 6 152 27 1 2 699 15 381 10 254 20 1 2 521 53 1 2 1359 N A STEP TOP 10 1 2 267 4 102 22 559 9 229 2 51 15 381 49 1 2 1283 N A INSTALLATION ALCOVE DOUBLE WALL PIPE MILLENNIUM 16 406 10 254 27 686 14 1 2 ...

Страница 13: ...gh the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures uneven r...

Страница 14: ...structions for clearance securing flashing and terminating the chimney Fig 14 1 14 2 Must have an approved and Listed cap Must not be located where it will become plugged by snow or other material Must terminate at least 3 feet 91cm above the roof and at least 2 feet 61cm above any portion of the roof within 10 feet 305cm Must be located away from trees or other structures NOTICE Chimney performan...

Страница 15: ...00o F or ULC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installation D Chimney Height Rise and Run This product was designed for and tested on a 6 inch 152mm chimney 14 to 16 feet 420 480cm high includes appliance height measured from the base of the appliance...

Страница 16: ...imum recommended by chimney connector manu facturer Figure 16 2 Instructions 1 Open inside wall at proper height for the chimney con nector to entry the masonry chimney Figure 16 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equiva lent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm outside dimension frame from 2 x...

Страница 17: ...FPA 211 Wall Spacer Wall Band Trim Collar Chimney Connector 1 inch 25mm Air Space to Chimney Section Min Clearance 2 inch 51mm Min Chimney Clearance to Wall Spacer and Combustibles 2 inch 51mm Chimney Section Figure 17 2 Solid Pack Chimney with Metal Supports as a Thimble Cont d G Installing Chimney Components Chimney Connector Single wall connector or appliance pipe This must be at least 24 gauge...

Страница 18: ...9 Install ARS latch by sliding latch assembly over 2 threaded studs protruding from the bottom on the left hand side of the appliance Secure by using two nuts use 7 16 socket wrench Figure 19 1 on page 19 10 Add knob to handle rod Figure 19 2 on page 19 11 Using two bolts and two flange nuts to secure ARS chan nel using 3 8 open end wrench and 7 16 socket wrench Figure 19 3 on page 19 CHECK GASKET...

Страница 19: ... 2 Install the ash drawer to pedestal base 3 Install ARS access cover inside of ARS Channel that is located inside the firebox Figure 20 2 on page 20 NOTE If installing a floor installation of an outside air kit on a Step Top model with a pedestal assembly you must attach the enclosed cover plate with 4 screw to the back of the stove Other wise you may discard this piece Figure 20 3 on page 20 CHE...

Страница 20: ...side 2 Remove the 2 bricks in the front most part of the firebox Figure 18 1 on page 18 3 Lay appliance on its back on a protective pad or pallet Figure 18 2 on page 18 4 Remove heat shield by loosening the four bolts using 3 8 open end wrench Figure 18 2 on page 18 5 Remove 8 nuts that hold the cover plate on using a 7 16 socket wrench discard cover plate Figure 18 2 on page 18 CHECK GASKET Verif...

Страница 21: ... phillips head screwdriver Start bottom two bolts through ash drawer leg brackets and into the bottom of the appliance Figure 21 1 Align top holes and repeat secure all four bolts 4 Install legs onto leg brackets making sure the legs are up against the bracket and secure with bolts and washers using a 3 8 open end wrench Figure 21 2 5 Install leveling bolts into 2 legs these leveling legs should b...

Страница 22: ...is a right and a left of the leg brackets Figure 22 1 5 Install six screws to the bottom of the leg brackets Figure 22 1 6 Attach legs onto leg brackets and secure with bolts and wash ers 7 Carefully stand stove up and place in desired location 8 Thread allen bolts through nuts until flush Figure 22 2 9 Slide allen bolt nut assemblies into slots of two of the legs with the nuts on the bottom Figur...

Страница 23: ...ead screw driver Silicone sealant Drills and saws necessary for cutting holes through the wall or flooring in your home Installation Instructions 1 Remove all materials from packing box 2 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly connect outside air to appliance intake ...

Страница 24: ...r should blow gently but should not stop G Blower Optional Tools Required 2 Phillips head screwdriver 1 Locate bolts supplied with the blower 2 Align holes in mounting flange of blower with bolt holes in appliance Blower should be positioned at bottom of rear outer skin as shown in Figure 24 1 3 Re insert and tighten bolts securing blower onto outer wall of appliance 4 Place the bracket containing...

Страница 25: ...pliance must be connected to a 6 inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use silicone to create an effective vapor bar...

Страница 26: ...26 7037 172 September 26 2016 4300 Wood Appliance Series ACC Date of Service Performed By Description of Service A Service Maintenance Log 7 Reference Materials ...

Страница 27: ...of 10 832 0860 Y Washer Sae 3 8 Pkg of 3 ea 832 0990 Y Washer 1 4 Sae Pkg of 24 28758 24 Y Service Parts R 43ST ACC B Beginning Manufacturing Date Sept 2016 Ending Manufacturing Date Active IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not sell directly to consumers Provide model number and serial number when requesting ser...

Страница 28: ...peration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pe...

Отзывы: