Switch(config-policymap-p1-class-c3)#exit
Switch(config-policymap-p1)#exit
Switch(config)#interface ethernet 1/1
Switch(config-if-ethernet1/1)#dot1q-tunnel enable
Switch(config-if-ethernet1/1)# service-policy p1 in
21.4 Flexible QinQ Troubleshooting
If flexible QinQ policy can not be bound to the port, please check whether the problem is
caused by the following reasons:
Make sure flexible QinQ whether supports the configured class-map and policy-map
Make sure ACL includes permit rule if the class-map matches ACL rule
Make sure the switch exists enough TCAM resource to send the binding