after processing the abnormity information, here, the user is able to know the abnormity
information and renew the monitoring.
13.2 DDM Configuration Task List
DDM configuration task list:
1. Show the real-time monitoring information of the transceiver
2. Configure the alarm or warning thresholds of each parameter for the transceiver
3. Configure the state of the transceiver monitoring
(1) Configure the interval of the transceiver monitoring
(2) Configure the enable state of the transceiver monitoring
(3) Show the information of the transceiver monitoring
(4) Clear the information of the transceiver monitoring
1. Show the real-time monitoring information of the transceiver
2. Configure the alarm or warning thresholds of each parameter for the transceiver
3. Configure the state of the transceiver monitoring
(1) Configure the interval of the transceiver monitoring
Command
Explanation
User mode, admin mode and global mode
show transceiver [interface ethernet
<interface-list>][detail]
Show the monitoring of the transceiver.
Command
Explanation
Port mode
transceiver threshold {default |
{temperature | voltage | bias | rx-power | tx-
power} {high-alarm | low-alarm | high-warn |
low-warn} {<value> | default}}
Set the threshold defined by the user.
Command
Explanation
Global mode
transceiver-monitoring interval
<minutes>
no transceiver-monitoring interval
Set the interval of the transceiver monitor. The
no command sets the interval to be the default
interval of 15 minutes.