WARRANTY 

 

Your  Ultrasonic  Processor  is  warranted  for  a  period  of  two  years

 

from  the  date  of 

shipment against defects in material and workmanship under normal use as described in 
this  instruction manual. During the  warranty  period,  the manufacturer  will,  at  its  option, 
as the exclusive remedy, either repair or replace without charge for material and labor, 
the  part(s)  which  prove  to  be  defective,  provided  the  unit  is  returned  to  us  properly 
packed with all transportation charges prepaid. 
 
Ultrasonic probes are guaranteed against defects for a period of one year from date of 
shipment. A defective probe will be replaced once without charge, if failure occurs within 
the warranty period. Wear resulting from cavitation erosion is a normal consequence of 
ultrasonic processing, and is not covered by this warranty. 
 
This warranty is in lieu of any other warranties, either express, implied, or statutory. The 
manufacturer  neither  assumes  nor  authorizes  any  person  to  assume  for  it  any  other 
obligations  or  liability  in  connection  with  the  sale  of  its  products.  The  manufacturer 
hereby  disclaims  any  warranty  of  either  merchantability  or  fitness  for  a  particular 
purpose. No person or company is authorized to change, modify, or amend the terms of 
this warranty in any manner whatsoever. Under no circumstances shall the manufacturer 
be  liable  to  the  purchaser  or  any  other  person  for  any  incidental  or  consequential 
damages  or  loss  of  goodwill,  production,  or  profit  resulting  from  any  malfunction  or 
failure of its product. 
 
This warranty does not apply to equipment that has been subject to unauthorized repair, 
misuse,  abuse,  negligence  or  accident.  Equipment  which,  shows  evidence  of  having 
been  used  in  violation  of  operating  instructions,  or  which  has  had  the  serial  number 
altered or removed, will be ineligible for service under this warranty. 
 
All  probes  are  manufactured  to  exacting  specifications  and  are  tuned  to  vibrate  at  a 
specific frequency. Using an out-of-tune probe will cause damage to the equipment and 
may  result  in  warranty  nullification.  The  manufacturer  assumes  no  responsibility  for 
probes  fabricated  by  another  party  or  for  consequential  damages  resulting  from  their 
usage. 
 
The aforementioned provisions do not extend the original warranty period of any product 
that has either been repaired or replaced by the manufacturer. 

 
 
 
 
 
 
 
 

one  year

2

Содержание CT2000

Страница 1: ...1 Sonicator ULTRASONIC PROCESSOR Part No Q2000 Q2000FCE OPERATION MANUAL Qsonica LLC 53 Church Hill Rd Newtown CT 06470 Phone 203 426 0101 www sonicator com Part No CT2000 1...

Страница 2: ...ereby disclaims any warranty of either merchantability or fitness for a particular purpose No person or company is authorized to change modify or amend the terms of this warranty in any manner whatsoe...

Страница 3: ...extremes in temperature and humidity Do not place the Generator within a Fume Hood x Hearing protection is highly recommended It is recommended that a sound abating enclosure or ear protection be used...

Страница 4: ...grams STANDARD PROBE PART NUMBER 4777 DIAMETER 1 5 37 mm LENGTH 9 6 244 mm REFERENCE ONLY ACTUAL TUNED LENGTH WILL VARY WEIGHT 2 0 lbs 900 grams REFERENCE ONLY ACTUAL WEIGHT WILL VARY WITH TUNED LENGT...

Страница 5: ...not configured to match the wall receptacle a properly grounded universal AC socket adapter must be added Important Universal adapters do not convert voltage or frequency The manufacturer is not resp...

Страница 6: ...C 50 60 Hz 20 amps If the desired plug type is different for your country or region see page 41 for a wiring diagram and consult an electrician INSTALLING THE ULTRASONIC PROCESSOR The ultrasonic proce...

Страница 7: ...ntensity Probe Part 4777 Note The compressed air hose for cooling the converter is not included Power Supply Converter CL 294 Booster 4121TI Probe 4777 Converter Cable 201 0106 Compressed Air Hose Opt...

Страница 8: ...9 Q2000 REAR PANEL Cooling Fan Converter Cable Connector Power Cord Connector Temperature Probe Connector Fuses Footswitch Jack DB9 Connector 8 REAR PANEL...

Страница 9: ...d with a Booster as shown below Note 4776 must not be used with the booster CL294 Converter 4676 Flocell Probe with Cover Plate 4697 Probe 4777 Probe 4776 Probe 4121TI Booster 39mm Flow Cell Probe 1 5...

Страница 10: ...12 Q2000 ASSEMBLY 1 Screw the converter to booster by hand 2 Set the Torque wrench to 64 5 ft lb Use the spanner wrench and Torque wrench to tightly attach the converter to the booster ASSEMBLY 10...

Страница 11: ...13 3 Screw the booster to the horn by hand 4 Set the Torque wrench to 64 5 ft lb Use the spanner wrench and Torque wrench to tightly attach horn to booster 11...

Страница 12: ...12 FLOW CELL ASSEMBLY 1 Mount o rings on horn 2 Slide flow cell lid over top of horn 3 Insert horn into flow cell align lid 4 Install 4 mounting bolts fully tighten by hand...

Страница 13: ...safe operating temperatures The elements of the system will still heat up when air cooling is employed but the converter will operate at an acceptable temperature for continuous use It is important to...

Страница 14: ...attage display During operation the wattage displayed is the energy required to drive the radiating face of a probe at that specific amplitude setting against a specific load at that particular moment...

Страница 15: ...sing network continuously monitors the output requirements and automatically adjusts the power to maintain the amplitude at the preselected level The greater the resistance to the movement of the prob...

Страница 16: ...Probe Options Part Tip Diameter Processing Volume Range Amplitude 4777 1 5 38mm 5 20L 100 m 4697 1 25mm 1 5L 100 m 4776 0 5 12mm 50 400ml 100 m Note Processing volumes are application specific There a...

Страница 17: ...e limit has been reached optional temperature probe must be used for this feature PULSER key Used with the numeric keys to set the pulse mode The ON cycle and OFF cycle can be set independently from 1...

Страница 18: ...upply frequency divided by 10 See schematic for ratings This output is referenced to pin 9 5 Power Output Watts Output Analog output representing power supply output wattage 5 44mV 1 Watt See schemati...

Страница 19: ...d or hot environment for a prolonged period of time Allow the system to reach room temperature before use CAUTION Never place a washer between the converter booster or probe Never apply grease to the...

Страница 20: ...4 key then the 0 key and then depress the ENTER REVIEW key The screen will display The Ultrasonic Processor is now ready for continuous operation To energize the equipment press the START key or the...

Страница 21: ...second OFF To set the processing time press the TIMER key The screen will display NOTE If the START key is pressed and the time limit has not been set processing will remain uninterrupted until the ST...

Страница 22: ...o allow the sample temperature to drop sufficiently The ON and OFF pulse duration can be set independently from 1 second to 59 seconds During the OFF portion of the cycle the red indicator on the PULS...

Страница 23: ...the setpoint If the temperature of the sample must be monitored and or controlled insert the optional temperature probe into the jack on the rear panel immerse the temperature probe in the sample and...

Страница 24: ...sed processing time e g Set 0 15 00 Time 0 10 00 c Selected pulsing cycle and actual pulsing cycle e g Pulse 30 15 d Amount of power in watts and accumulated amount of energy in JOULES delivered to th...

Страница 25: ...nics when the energy level reaches a predetermined setpoint To set the energy setpoint press the ENERGY key The screen will display Using the numeric keys set the energy setpoint The screen will displ...

Страница 26: ...ess the key one more time The screen will display Press the ENTER REVIEW key The screen will display Using the 1 9 numeric keys enter the ID number The screen will display Press the ENTER REVIEW key T...

Страница 27: ...The screen will display Use the 1 9 numeric keys enter the ID number The screen will display Pres the ENTER REVIEW key The screen will display Note To review all the information that has been stored p...

Страница 28: ...tch the unit back on to restart the equipment If the problem persists check for likely causes in the bulleted list below If the problem still persists contact customer service 203 426 0101 Your Sonica...

Страница 29: ...voltage is present in the cable and will pose a shock hazard Do not touch the converter assembly until the power switch is off and the unit is unplugged Probe Maintenance While operational the convert...