Options of Boot Management Settings
The options available in this tab:
Enable Auto Shutdown:
Check to enable auto shutdown. If enabling the setting, the
system will shutdown automatically when the internal power levels or temperature are
not within normal levels.
TIP:
For better protection and to avoid a single short period of abnormal
voltage or temperature, enabling the setting could trigger an automatic
shutdown. This is done using several sensors placed on key systems that
the system checks every 30 seconds for present voltages or
temperatures. The following items are trigger conditions.
The value of voltage or temperature is lower than
Low Critical
or
higher than
High Critical
.
When one of these sensors reports above the threshold for three
contifuous minutes, the system will be shutdown automatically.
For more information about critical values, please refer to the chapter
13.2.1,
section in the Monitoring chapter.
Enable Wake-on-LAN:
Check to enable wake-on-LAN, the system will accept a magic
packet from management port to power on the system.
TIP:
To execute wake-on-LAN function, MAC address of management port is
needed. For the information of MAC address, please refer to the chapter
6.2,
Enable Wake-on-SAS:
Check to enable wake-on-SAS. If Wake-on-SAS is enabled, and
connect the XD5300 series expansion unit(s) with the proprietary Wake-on-SAS
expansion cable(s), the XD5300 series will power on or shutdown in conjunction with the
head unit.
Содержание XCubeSAN XS5224D
Страница 71: ...SANOS User Interface 49 nnnnn RPM Power Supply Local PSU n status Reset to Default Yes No...
Страница 99: ...System Settings 77 Figure 6 14 System Information...
Страница 315: ...Monitoring 293 Figure 13 5 Hardware Monitoring...
Страница 327: ...Support and Other Resources 305 Figure 15 1 Download Service Package in the SANOS UI...
Страница 331: ...Support and Other Resources 309...