Storage Management
117
A SANOS system can contain up to 4,096 LUNs which includes the total of volume LUN
mappings and snapshot volume LUN mappings.
Table 8-5
LUN Parameters
Item
Value
Maximum Quantity of LUN
4,096
For more information about LUN mapping operation, please refer to the chapter 8.6,
8.2.4.
Hot Spares
A hot spare disk is a disk used to automatically or manually replace a failing or failed disk in
a RAID configuration. The hot spare disk reduces the MTTR (Mean Time To Recovery) for
the RAID redundancy group, thus reducing the probability of a second disk failure and the
resultant data loss that would occur in any singly redundant RAID (e.g., RAID 1, RAID 5, or
RAID 10). Typically, a hot spare is available to replace some different disks and systems
employing a hot spare normally require a redundant group to allow time for the data to be
generated onto the spare disk. During this time the system is exposed to data loss due to a
subsequent failure, and therefore the automatic switching to a spare disk reduces the time
of exposure to that risk compared to manual discovery and implementation.
If one disk drive of the pool fails or has been removed from any singly redundant RAID, the
pool status will change to degraded mode. At the moment, the SANOS system will search
the spare disk to execute pool/volume/data rebuild into a healthy RAID drive.
There are three types of spare disk drive which can be set in function menu
Disks
:
Dedicated Spare
: Set a spare disk drive to a dedicated pool.
Local Spare
: Set a spare disk drive to the pools which located in the same enclosure.
The enclosure is either in head unit or in one of expansion units.
Global Spare
: Set a spare disk drive to all pools which located whether in head unit and
expansion unit.
Содержание XCubeSAN XS5224D
Страница 71: ...SANOS User Interface 49 nnnnn RPM Power Supply Local PSU n status Reset to Default Yes No...
Страница 99: ...System Settings 77 Figure 6 14 System Information...
Страница 315: ...Monitoring 293 Figure 13 5 Hardware Monitoring...
Страница 327: ...Support and Other Resources 305 Figure 15 1 Download Service Package in the SANOS UI...
Страница 331: ...Support and Other Resources 309...