108 ©
Copyright 2017 QSAN Technology, Inc. All Right Reserved.
8.
Storage Management
This chapter describes storage technologies of RAID, storage pool, volume, and LUN
mapping. Also includes the details of storage management operations and examples. The
STORAGE MANAGEMENT
function menu provides submenus of
Disks
,
Pools
,
Volume
, and
LUN Mappings
. In this chapter, we will focus on the fundamental storage architecture called
thick provisioning. The advanced storage features and functions will be described in the
following.
Thin Provisioning feature is described in the
Auto Tiering feature is described in the
SSD Cache feature is described in the
The data backup functions are described in the following sections.
Snapshot function is described in the
Local Clone function is described in the
Remote Replication function is described in the
8.1.
RAID Technology
RAID is th
e abbreviation of Redundant Array of Independent Disks. The basic idea of RAID is
to combine multiple drives together to form one large logical drive. This RAID drive obtains
performance, capacity and reliability than a single drive. In point view of the host, the
operating system in host detects the RAID drive as a single storage device.
The disk drives in storage are referred to as members of the array. Each array has a RAID
level. RAID levels provide different degrees of redundancy and performance. They also have
different restrictions regarding the quantity of member disk drives in the array. The
following describe the features of RAID levels.
RAID 0 (Striping, no redundancy)
RAID 0 consists of striping, without mirroring or parity. It has more than two disks in parallel,
as a large-capacity disk. The capacity of a RAID 0 volume is the sum of the capacities of the
disks. There is no added redundancy for handling disk failures. Thus, failure of one disk
causes the loss of the entire RAID 0 volume. Striping distributes the contents roughly
equally among all member disks, which makes concurrent read or write operations on the
multiple disks and results in performance improvements. The concurrent operations make
Содержание XCubeSAN XS5224D
Страница 71: ...SANOS User Interface 49 nnnnn RPM Power Supply Local PSU n status Reset to Default Yes No...
Страница 99: ...System Settings 77 Figure 6 14 System Information...
Страница 315: ...Monitoring 293 Figure 13 5 Hardware Monitoring...
Страница 327: ...Support and Other Resources 305 Figure 15 1 Download Service Package in the SANOS UI...
Страница 331: ...Support and Other Resources 309...