4

5

2.2 

Response to Emergency Situations

2.2.1 

Leaking Batteries

If the battery leaks electrolyte which is corrosive, avoid contact with the leaking 

liquid or gas. Direct contact may lead to skin irritation or chemical burns. If one is 

exposed to the leaked substance, perform these actions:

Accidental inhalation of harmful substances:

 Evacuate from the contaminated 

 

area, and seek medical attention immediately.

Eye contact:

 Rinse eyes with flowing water for 15 minutes, and seek medical 

attention immediately.

Dermal contact:

 Wash the affected area thoroughly with soap and water, and 

seek medical attention immediately.

Ingestion:

 Induce vomiting, and seek medical attention immediately.

2.2.2 

Fire

In case of a fire, ensure that an ABC or a carbon dioxide extinguisher is nearby.

If a fire breaks out where the battery module is installed, perform 

these actions:

1) Extinguish the fire before the battery module catches fire

2) If the battery module catches fire, do not try to

extinguish

 the fire. Evacuate immediately.

2.2.3 

Wet Batteries and Damaged Batteries

If the battery module is wet or submerged in water, do not try to access it. 

If the battery module seems to be damaged, it is not fit for use and may pose  

a danger to people or property.

Please pack the battery in its original packaging, and return it to Q CELLS or your  

distributor.

WARNING!

The battery module may catch fire when heated 

above 302°F.

WARNING!

If the battery module catches fire, it will produce noxious and poisonous 

gases. Do not approach.

CAUTION!

Damaged batteries may leak electrolyte or produce flammable gas. If 

you suspect such damage, immediately contact Q CELLS for advice  

and information.

INSTALLATION AND OPERATION MANUAL LITHIUM-ION BATTERY – Q CELLS

2. Safety

2. Safety

Wear protective glasses.

Observe enclosed documentation.

Keep the battery system away from open flames or ignition

sources.

Keep the battery system away from children.

The battery module may explode.

Symbol

Explanation

CSA mark for UL1973

TUV mark for IEC62619

The battery system must be disposed of at a proper facility 

for environmentally-safe recycling.

US

R

The battery system should not be disposed of together 
with household waste. Disposal information can be found 
in the enclosed documentation. 

Danger of high voltages.

Danger. Risk of electric shock.

INSTALLATION AND OPERATION MANUAL LITHIUM-ION BATTERY – Q CELLS

Содержание Q.HOME ESS HYB-G1

Страница 1: ...Q HOME ESS HYB G1 Lithium Battery Series 45Ah 63Ah Valid for North America INSTALLATION AND OPERATION MANUAL Hanwha Q CELLS America Inc 614 00447 01...

Страница 2: ...LLER 3 PRODUCT INTRODUCTION 3 1 PRODUCT OVERVIEW 3 1 1 DIMENSIONS AND WEIGHT 3 1 2 APPEARANCE 3 2 BASIC FEATURES 3 2 1 FEATURES 3 2 2 CERTIFICATIONS 3 3 SPECIFICATIONS 3 3 1 Q HOME BAT G1 CONFIGURATIO...

Страница 3: ...SIONING 5 1 CONFIGURING BATTERY SYSTEM 5 2 COMMISSIONING 5 3 STATUS INDICATORS 5 3 1 BMS Master Box 5 3 2 BATTERY MODULE BAT45 BAT63 5 4 SHUTTING DOWN Q HOME BAT G1 SYSTEM 6 TROUBLESHOOTING 6 1 TROUBL...

Страница 4: ...ON AND OPERATION MANUAL LITHIUM ION BATTERY Q CELLS Observe the following precautions Risks of explosion Risks of fire Do not subject the battery module to heavy impacts Do not crush or puncture the b...

Страница 5: ...wet or submerged in water do not try to access it If the battery module seems to be damaged it is not fit for use and may pose a danger to people or property Please pack the battery in its original pa...

Страница 6: ...fore performing installation 3 1 1 Dimensions and Weight A battery management system BMS is any electronic system that manages a rechargeable battery A battery module is a type of electrical battery w...

Страница 7: ...tion view of Q HOME BAT G1 Object Mark Description I II III IV V VI XPLUG RS485 I GND RS485 II YPLUG Power Connector to BMS or YPLUG of upper battery module RS485 Connector to BMS or RS485 II of upper...

Страница 8: ...3 BAT12 6 BAT18 9 BMS BAT BMS G1x1 BAT BMS G1x1 BAT BMS G1x1 BAT BMS G1x1 BAT BMS G1x1 BAT BMS G1x1 Battery Module Q HOME BAT G1 4 5X1 Q HOME BAT G1 4 5X2 Q HOME BAT G1 4 5X3 Q HOME BAT G1 6 3X1 Q HO...

Страница 9: ...Flat Head Screw Driver Torque Wrench Tape Measure Drill Pencil or Marker 4 4 Installation 4 4 1 Check for Transport Damage Ensure the battery is intact during and after transportation If there are vis...

Страница 10: ...ty 1 1 1 1 1 1 1 1 1 1 1 1 4 10 A B C E D F G I H J K L M N Battery Module BAT45 BAT63 Quantity 1 1 1 1 5 1 2 12 1 1 2 Object A1 B1 C1 D1 E1 F1 G1 H1 I1 J1 K1 Description Power Cable between Battery M...

Страница 11: ...ed to ambient air The system is cooled by natural convection If the system is entirely or partially covered or shielded it may cause the system to stop operating CAUTION CAUTION The space between batt...

Страница 12: ...Connection 4 5 1 Connecting Power Cables For one battery module The color at both ends of the power cable between the BMS and battery module C is orange This cable is connected to the XPLUG which is o...

Страница 13: ...er K1 unlocked until the cables are correctly connected to the YPLUG Refer to the installation diagram on the right 5 On the right side of the BMS after the charging cables refer to section 4 5 5 and...

Страница 14: ...r use 3 Push the plastic button on each end of the power cable in the direction of the arrow Notes for Unplugging Power Cables Lock Cover 22 23 DANGER CAUTION Do not plug or unplug the power cables wh...

Страница 15: ...I RS485II VCC_485 VCC_485 GND_485 GND_485 B2 B2 N N P P A2 A2 VCC_485_2 VCC_485_2 GND_485 GND_485 The wire order of the communication cable is as follows 1 2 3 4 5 6 7 8 1 Orange stripes on white 2 Or...

Страница 16: ...ect port on both the inverter and BMS 2 Connect the negative cable B to the port on the right and the positive cable A to the port on the left 4 5 5 Connecting the Charging Cables This step details in...

Страница 17: ...stem installation with terminal boxes and conduit Installers are responsible for preparing conduit according to AHJ requirements Conduit size shall be 0 5in for the smaller hole and 1 1 25in for the l...

Страница 18: ...onfigure the DIP VI to the corresponding number according to the number of battery module s that has have been installed 2 Remove the cover board of the BMS 3 Move the circuit breaker switch V to the...

Страница 19: ...e LED indicators flash once evey 5 seconds The following table shows the status of the BMS Capacity Status Capacity Status Charging Discharging 5 3 2 Battery Module BAT45 BAT63 5 4 Shutting Down Q HOM...

Страница 20: ...protection BMS_DishargeOCP Battery discharge over current protection Warning Messages Description Troubleshooting 6 Troubleshooting BMS_TemHigh Battery over temperature BMS_TemLow Battery under temper...

Страница 21: ...efects that result from the following causes Force majeure flooding lightning strike overvoltage fire thunderstorm flooding etc Improper or noncompliant use Improper installation commissioning start u...

Отзывы: