70
Periodic short and long flashes will be seen when communications occur on a modbus
network that contains multiple modbus slave devices.
If only short flashes are seen:
•. Check.the.inverter.modbus.address.switches.and.make.sure.they.correspond.to.the.
address.programmed.into.the.modbus.master.
•. Confirm.that.the.baud.rate.and.other.communication.parameters.of.the.modbus.mas-
ter.are.set.correctly.
For further modbus network configuration details see
Appendix E - Annual Maintenance
Requirements Checklist
.
7.7 Controller PCB Status Light Operation
There are two lights on the front of the Controller PCB, a green and a red light.
If the green light is on:
•. The.inverter.is.on.and.ready.to.produce.power.
If the red light is on:
•. Solid.red.—.the.inverter.is.in.a.faulted.condition.that.will.be.auto.reset.by.the.inverter.
if.the.fault.condition.is.cleared.
•. Flashing.red.—.there.is.a.latching.fault..A.latching.fault.requires.manual.intervention.
prior.to.the.inverter.restart.
If the red light is on or flashing, a fault code should be shown on the display. See
Appendix D - Limits and Fault Codes
for a description of the fault codes.
Содержание PVP260kW
Страница 1: ...97 600100 24 B02 PVP260kW Inverter INSTALLATION OPERATION MANUAL ...
Страница 2: ......
Страница 4: ...ii ...
Страница 6: ...iv ...
Страница 8: ...vi ...
Страница 48: ...36 ...
Страница 62: ...50 ...
Страница 86: ...74 ...
Страница 87: ...75 Appendix C Mechanical Drawings Figure C 1 Mechanical Drawings APPENDIX C ...
Страница 88: ...76 Figure C 2 Mechanical Drawings ...
Страница 94: ...82 ...
Страница 96: ...84 ...
Страница 104: ...92 Notes ...
Страница 105: ......
Страница 106: ...PO Box 7348 Bend OR 97708 P 541 312 3832 www pvpowered com ...