![PV Powered PVP260kW Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/pv-powered/pvp260kw/pvp260kw_installation-and-operation-manual_1628547057.webp)
45
PVP260kW Inverter
Installation and Operation Manual
Response Information
Response
Layout
CRC LSB
xx
CRC MSB
xx
Table 5-7 Format for Write Single Register, response to command 06
Return Slave ID
Command Information
Command
Layout
Modbus slave address
nn (1-126)
Command number
11h
Table 5-8 Format for Return Slave ID, command 11h
The Slave ID command returns the ASCII string “
xxPVP Inverter IDxxxxx
”, for example
“
0x50,0xFF,PVP Inverter ID02860910080321
”. The first “
xx
” represents two non-ASCII
bytes, representing the following information:
Byte 1: 0x50 - An identifier byte for PVP inverters
Byte 2: 0x00 - If communication with the inverter is down,
0xFF - If communication with the inverter is okay.
Byte 3 through byte n: Contains “
PVP Inverter IDxxxxx
”.
Response Information
Response
Layout
Modbus slave address
nn (1-126)
Command number
11h
Number of bytes of data
n
Data 1
xx
Data 2
xx
Data n
xx
CRC LSB
xx
CRC MSB
xx
Table 5-9 Format for Return Slave ID, response to command 11h
Содержание PVP260kW
Страница 1: ...97 600100 24 B02 PVP260kW Inverter INSTALLATION OPERATION MANUAL ...
Страница 2: ......
Страница 4: ...ii ...
Страница 6: ...iv ...
Страница 8: ...vi ...
Страница 48: ...36 ...
Страница 62: ...50 ...
Страница 86: ...74 ...
Страница 87: ...75 Appendix C Mechanical Drawings Figure C 1 Mechanical Drawings APPENDIX C ...
Страница 88: ...76 Figure C 2 Mechanical Drawings ...
Страница 94: ...82 ...
Страница 96: ...84 ...
Страница 104: ...92 Notes ...
Страница 105: ......
Страница 106: ...PO Box 7348 Bend OR 97708 P 541 312 3832 www pvpowered com ...