Nixie Tube Clock ‘Elite’
Issue 3 (25 July 2018)
www.pvelectronics.co.uk
- 26 -
To prevent excess stray light, you can add small pieces of the 5mm
heat shrink over the LEDs. It is not necessary to shrink the tubing.
If you choose to shrink it, be careful as it may shrink so narrow
that almost no light comes out.
5.14 Antenna wire
Strip 3mm insulation from the end of the wire supplied and cut the
wire to 17cm length. Solder the wire to the ANT pad as shown
below.