background image

User Manual

PT-IPAV-E2

Asking for Assistance

Technical Support:

Phone:  +49 5971 800299 - 0
Fax: 

+49 5971 800299 - 99

Technical Support Hours:

8:30 AM to 5:00 PM Monday thru Thursday
8:30 AM to 4:00 PM Friday

Write To:

PureLink GmbH
Von-Liebig-Straße 10

D - 48432 Rheine

www.purelink.de
[email protected]

LIMITED WARRANTY LIMITS AND EXCLUSIONS

a. 

This  Limited  Warranty  ONLY  COVERS  failures  due  to  defects  in  materials  or  workmanship,  and  DOES  NOT 
COVER normal wear and tear or cosmetic damage. The Limited Warranty ALSO DOES NOT COVER damages 

which occurred in shipment, or failures which are caused by products not supplied by warrantor, or failures 
which result from accidents, misuse, abuse, neglect, mishandling, misapplication, alteration, faulty installation, 
set-up adjustments, misadjustment of consumer controls, improper maintenance, power line surge, lightning 

damage, modification, or service by anyone other than a Factory Service center or other Authorized Server, or 

damage that is attributable to acts of God.

b. 

THERE  ARE  NO  EXPRESS  WARRANTIES  EXCEPT  AS  LISTED  UNDER  „LIMITED  WARRANTY  COVERAGE“.  THE 
WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF 
THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRNTY. (As examples, this excludes damages 

for lost time, cost of having someone remove or re-install an installed unit if applicable, travel to and from 
the service, loss of or damage to media or images, data or other recorded content. The items listed are not 

exclusive, but are for illustration only.)

c. 

PARTS AND SERVICE, WHICH ARE NOT COVERED BY THIS LIMITED WARRANTY, ARE YOUR RESPONSIBILITY.

Содержание PT-IPAV-E2-RX

Страница 1: ...User Manual PT IPAV E2 User Manual 2K HDMI over IP Extender with IR and RS232 Model PT IPAV E2 TX PT IPAV E2 RX Designed in Germany 2017 PureLink GmbH All rights reserved Version 1 0 ...

Страница 2: ... up to 15Mbps 5 Support LPCM audio format 6 Smart IP Address Setting Dynamic Host Configuration Protocol DHCP 7 Wide band IR pass through to control the source 38khz to 56khz 8 By pass 2 way UART RS232 Up to 115200 use remote controller to select 8 group Baud rate 9 Support one to one one to many many to one many to many modes with large cascade 10 Dual power input 802 3af compliant POE DC 5V No n...

Страница 3: ...outer Support IGMP support DHCP Connectors on Transmitter Input 1xHDMI Female port Output 1x RJ45 output 1x HDMI looping output RS232 Phoenix RS232 port IR IR TX port Support 38K 56KHz IR Ext port Support 38KHz Connectors on Receiver Input 1xRJ45 input Output 1x HDMI Female port looping output RS232 Phoenix RS232 port IR IR RX port Support 38K 56KHz IR Ext port Support 38KHz Environmental Power Re...

Страница 4: ... Resolution 50Hz 576i 576P 720P 1080P 1080i 60Hz 59 94Hz 480i 480P 720P 1080P 30Hz 29 97Hz 1080P 24Hz 1080P 25Hz 1080P 3 2 VESA resolution Frequency Resolution 50Hz 576i 576P 720P 1080P 1080i 60Hz 59 94Hz 480i 480P 720P 1080P 30Hz 29 97Hz 1080P 24Hz 1080P 25Hz 1080P ...

Страница 5: ...or of data status 3 Red indicator of power input 4 HDMI output for local display 5 HDMI input 6 CAT5e 6 output 7 IR TX 8 RS232 port 9 IR Ext 10 LED to show the Group ID 11 Press the button for the previous Group ID 12 Press the button for the next Group ID 13 Reset button 1 DC 5V 1A input 2 Green indicator of data status 3 Red indicator of power input 4 HDMI output 5 CAT5e 6 input 6 IR RX 7 RS232 ...

Страница 6: ...User Manual PT IPAV E2 6 How to connect the IR Cable 4 1 Panel Drawing Transmitter ...

Страница 7: ...connecting point to many many to point and many to many please make sure every TX and RX has unique IP and MAC address every TX has unique group ID Our this over IP Extender has been assigned unique default MAC address for every TX and RX so you don t have to set the MAC for the units You just need to set the IP address and Group ID following bellowing steps ...

Страница 8: ...ame domain Access the Network Setting Control Panel in Windows and locate your Lan connection Under Windows 7 this can be done by clicking Start Control Panel Network Sharing center Change adapter settings Properties Internet Protocol Version4 TCP IPv4 Change the IP address field to 192 168 1 1 0 255 After that press OK to save the configuration NOTE The PC and TX RX should be in the same domain T...

Страница 9: ...e LED will flicker then turn to 00 you have successfully finished the factory reset Choose Group ID 00 63 1 Press or to change to the previous or next Group ID 2 Press the No to change Group ID For example if you need change to 01 press 0 then press 1 Choose the Baud Rate Press the Button switch to Baud Rate mode press or to change the Baud Rate F0 F1 F2 F3 F4 F5 F6 F7 2400 default 4800 9600 19200...

Страница 10: ...ED for the extender is red and the green status LED is blinking Step 3 Power on the TX or RX with 5V 1A power supply Step 4 Login in IE 192 168 1 11 default IP for TX or 192 168 1 12 default IP for RX TX requires user name admin and password admin Step5 Change the group ID at Stream setting 00 means group 00 here which can be chosen from 00 to 63 Step 6 Click Submit transmitter or update receiver ...

Страница 11: ...t 1 Connect the source device and the Transmitter unit with HDMI Cable 2 Connect the HDMI looping output of the Transmitter to the local HDMI display 3 3 Connect another HDMI display and the HDMI Receiver unit with HDMI Cable 4 Connect the Transmitter and Receiver with Cat5e 6 cable 5 Connect the IR TX cable into IR TX port of the transmitter Connect the IR RX cable into IR RX port of the receiver...

Страница 12: ...eceivers and the switch router with Cat5e 6 cable 6 Connect the HDMI displays and the HDMI Receiver units with HDMI Cable 7 Connect the IR TX cable into IR TX port of the transmitter Connect the IR RX cable into IR RX port of the receiver Then you can control the source at the RX side with IR 8 Connect one RS 232 Cable from the PC or automation system to the RS 232 port on the Transmitter Connect ...

Страница 13: ...th HDMI Cable 7 Connect the IR TX cable into IR TX port of the transmitter Connect the IR RX cable into IR RX port of the receiver Then you can control the source at the RX side with IR 8 Connect one RS 232 Cable from the PC or automation system to the RS 232 port on the Transmitter Connect one RS 232 cable from the Receiver to the RS 232 device to be controlled 9 Power on Transmitter and Receiver...

Страница 14: ...User Manual PT IPAV E2 14 Note The total qty of TX RX Switch is less than 256pcs ...

Страница 15: ...Rate which range from default 2400 to 115200 7 Firmware update We provide the firmware to upgrade the units when it is necessary Please follow up bellowing steps to update the firmware Step1 Connect TX RX to the PC with a short Cat5e cable Step2 Power on TX RX with power adapter 5V1A Step3 Login TX or RX with their default IP TX 192 168 1 11 RX 192 168 1 12 on web browser TX requires user name adm...

Страница 16: ...2 16 8 One key recovery to default setting 9 PC Tool Instructions Step 1 Make sure the Transmitter and PC are in the same domain Refer to 5 1 1 Step 2 Open the PC Tool Step 3 Click Start Scan Step 4 Choose the TX or RX Name ...

Страница 17: ...User Manual PT IPAV E2 17 9 1 Firmware Upgrade Upgrade for TX Step 1 Click Firmware Upgrade Step 2 Click Upgrade Encoder FW first ...

Страница 18: ...User Manual PT IPAV E2 18 Step 3 After the step 2 is finished click Firmware Upgrade again then click Upgrade TX FW Upgrade for RX Step 1 Click Firmware Upgrade Step 2 Click Upgrade Rx FW ...

Страница 19: ...nual PT IPAV E2 19 9 2 Other settings Step 1 Change the IP Netmask Gateway DHCP Uart Baudrate Group ID Mac Address Device name on the PC tool interface Step 2 Click Update after Update is finished click Reboot ...

Страница 20: ... are in the same domain Refer to 5 1 1 Step 2 Connect the HDMI Source without HDCP with the transmitter and power on the device Step 3 Connect the transmitter to the PC Step 4 Check the Multicast Group on the web refer to 5 1 3 Step 5 Open the VLC media Player click Stream Network Input UDP 239 255 42 42 5004 Note 239 255 42 42 Multicast Group 5004 Port ...

Страница 21: ...User Manual PT IPAV E2 21 Step 6 Click Next Step 7 Choose RTP MPEC Transport Stream ...

Страница 22: ...User Manual PT IPAV E2 22 Step 8 Click Next Step 9 Click Stream Step 10 Click Open Network Stream then you can click Play to view the video ...

Страница 23: ...l be made by the warrantor During the Labor Limited Warranty period there will be no charge for labor During the Parts warranty period there will be no charge for parts You must mail in your product during the warranty period This Limited Warranty is extended only to the original purchaser and only covers product purchased as new A purchase receipt or other proof of original purchase date is requi...

Страница 24: ...ation alteration faulty installation set up adjustments misadjustment of consumer controls improper maintenance power line surge lightning damage modification or service by anyone other than a Factory Service center or other Authorized Server or damage that is attributable to acts of God b THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED UNDER LIMITED WARRANTY COVERAGE THE WARRANTOR IS NOT LIABLE ...

Отзывы: