31
Ⅳ
. Maintenance
Condition
Thing(s) to Check
Situation
Measures
Cannot start
operation
Slippage
Electric
Accident
Power leakage
Electricity leaked
along main body &
wire rope
☞ Ground completely.
☞ Check insulation.
☞ Remove moisture and dry up.
Slipping during stop mode?
Wire rope abrasion
Change wire rope
Pulley groove abrasion
Change pulley
Cannot work
the load.
Is wire hook
inserted properly?
Is load weight
within capacity?
Is power on?
In-put power
switch is turned
off.
In-put power
source produces
excessive noise and heat.
☞ Press switch firmly.
☞ Connect power line properly.
☞ Check power cable.
☞ Check power voltage.
☞ Check condition of
in-put power source.
☞ Work load within capacity.
11. Trouble-Shooting
※
When operation is abnormal, take measures according to instructions in Trouble-Shooting of this manual.
For other abnormalities, contact your dealer or manufacturer.
12. Education and Training for User
Operator of PULLEY-MAN or maintenance personnel must acquaint himself with daily and periodical check
points and safety rules in this manual. Also, appropriate education must be provided to ensure maintenance
in a timely manner. When troubles arise, take measures according to instructions in Trouble-shooting of this
manual.
Содержание CSW-3060
Страница 1: ...www pulleyman co kr PULLEY MAN CO Ltd CSW 3060 Single Line Use Double Line Use...
Страница 11: ...10 Uses and Operations 1 Standard Offerings and Options AC Motor Double Line Options CSW 3060...
Страница 36: ...35 MEMO...
Страница 37: ...36 MEMO...