Operation, Calibration & Service Manual
LinkBelt - DS350 1334 Console
System Function
Upon switching on crane ignition switch, the system starts with
an automatic test of the LMI system, of lamps and audible
alarm. During the test, the LC display shows the initial logo.
(approximately 35 seconds)
The previous configuration setup will be displayed showing bold
symbols as selected inputs and must be confirmed OK to set the
system into operation or deleted to enter a new configuration.
(
chapter 4)
The operating configuration is determined by an interactive step-
by-step interrogation of the rigging states and reeving.
(
chapter 4)
The configuration setup entered will be displayed showing bold
symbols as selected inputs and must be confirmed OK to set the
system into operation or deleted to enter a new configuration.
(
chapter 4)
The console has 3 functions:
Upon acknowledgment of the inputs the system is ready for
operation.
Operating Console
inputs by the crane operator (operating configuration, reeving, and calibration)
input of geometry limit values and signalization of exceeded limit values
display of important data and information
The operator’s console is mounted in the crane’s cab in the operator’s field of vision. For a better
identification of displays and operating elements, they are continuously backlit during operation.
START
SELF TEST
OK or DEL
operating
configuration
NO
YES
Interactive INPUT
operating configuration
NO
OK or DEL
operating
configuration
YES
OPERATIONAL