Operation, Calibration & Service Manual
LinkBelt - DS350 1334 Console
Ji b Calibration
Step J1:
Boom to the indicated angle
0.5
. With the block
suspended, enter the weight of the hook block.
NOTE: There is
to be no load on hook at this time.
Use the + and
– button to
change the value shown. Press OK when complete.
Note: the angle will be automatically selected based on the
minimum angle allowed by the selected operating mode.
Step J2:
Take a radius measurement from the centerline of
rotation to the block/ball. Enter the actual measured radius. Use
the + and
– button to change the value shown. Press OK when
complete
Step J3:
Boom to the indicated angle
0.5
. Take a radius
measurement from the centerline of rotation to the block/ball.
Enter the actual measured radius.
NOTE: There is to be no load
on hook at this time.
Use the + and
– button to change the value
shown. Press OK when complete.
Note: the angle will be automatically selected based on the
following formula:
max
angle
min
angle
2
min
angle