VIBSCANNER 11.2010
20
D
ISPLAY
: (Continued)
O
VERALL
VALUES
: Standard display for the results of a
vibration measurement (RMS + Crest (factor) / RMS +
0-P / RMS + P-P / 0-P + P-P).
S
CALING
(
FOR
)
SPECTRUM
: Amplitude as 0-P / RMS value
D
ATE
& T
IME
: Click on ‘Select’ to change the following
settings:
D
ATE
& T
IME
: Click on ‘Select’ and set date and time:
Getting started
• Move the cursor to the left / right to select the year,
month, day and time.
• Push the joystick up (down) to increase (to decrease)
the value.
• Click the joystick to accept the settings
D
ATE
FORMAT
: The available selection is: DD-MM-YYYY /
MM-DD-YYYY / YYYY–MM–DD
D
AYLIGHT
SAVING
: Selected time corresponds to summertime
(‘Yes’) or wintertime (‘No’).
T
IME
ZONE
: Time shift for ‘Greenwich mean time’ (GMT).
T
IME
FORMAT
: HH:mm:ss / hh:mm:ss xx* / hh:mm:ssxx*
U
NITS
: Click on ‘Select’ to set the units (ISO/US) for the
following parameters:
- Vibration acceleration, velocity, displacement,
- Temperature,
- Speed
- Frequency
- Mass (only in the optional balancing module)
- Length/ radius (only in the optional balancing module)
- Production line speed (only in ‘Route mode’)
L
ANGUAGE
: Click on ‘Select’ to change the dialog language;
Delete any languages that you do not need with ‘Del.’
(Delete).