/ŶƐƚĂůůĂƚŝŽŶ͕KƉĞƌĂƚŝŽŶĂŶĚDĂŝŶƚĞŶĂŶĐĞ DĂŶƵĂů
d>͘ϯϭ͘ϮϭϬͲ/KD͘E
^ĞĐƚŝŽŶϰ͗/ŶƐƚĂůůĂƚŝŽŶ
:ƵůϮϬϭϲ
/ŶƐƚĂůůĂƚŝŽŶ
ϭϱ
ϱ͘
Install the actuator to the bracket. Tighten all bolts and apply the correct
torque
(refer to Table 8).
Table 8.
Bottom flange torque values
Actuator Size
ISO Pattern
Torque (Nm)
Torque (lbf.ft)
Thread
Min.
Max.
Thread
Min.
Max.
32
F03
M6
4.5
5
10-24UNC
3.3
3.7
40, 52
F03 inner pattern
M5
2.0
3.0
10-24UNC
1.5
2.2
F05 outer pattern
M6
4.5
5.0
1/4"-20
3.3
3.7
63, 75, 83, 92
F05 inner pattern
M6
4.5
5.0
1/4"-20
3.3
3.7
F07 outer pattern
M8
10.5
12.5
5/16"-18
7.7
9.2
105, 125
F07 inner pattern
M8
10.5
12.5
5/16"-18
7.7
9.2
F10 outer pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
140, 160
F10 inner pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
F12 outer pattern
M12
34.5
43.0
1/2"-13
25.4
31.7
190, 210, 240, 270,
300
ϲ͘
When required, mount or adjust the visual indicator (22).
Figure 12
Indicator mounting
"In Line mounting"
"Across Line mounting"
ϰ͘ϲ
Mounting of control and feedback accessories
Solenoid valve and or switch boxes can now be mounted to the actuator. Check
the instructions as shipped with these components for installation, operating
and maintenance instructions.
We recommend to test-cycle the complete assembly to check correct operation.