COMPACT 2 NDT
User Manual
5190-0-0002
PROTEC GmbH & Co. KG, In den Dorfwiesen 14, 71720 Oberstenfeld, Germany
25 von 65
5.2.8
Dryer temperature
The dryer temperature can be adjusted within a range of 35-70 °C according to the different film-
materials. To avoid dryer spots on the film, the dryer temperature may not be set too high. Adjust the
temperature so that the film just gets dry (Setting the dryer temperature: see “Working Parameters”
5.2.5.2).
Remark: Depending on mains voltage dryer temperatures above 65°C may under certain circumstances
not be reached.
CAUTION!
High or low room temperature can influence the function of the film
processor.
5.2.9
Replenishment time
The replenishment of the developer and fixer chemicals is automatic. By means of the light barrier
electronic at the film-infeed, the surface of the processed films are calculated and after 0.25 m²
a
replenishment cycle is automatically activated. The replenishment quantity can be adjusted varying for
developer and fixer by adjusting the replenishment time. The replenishment time may be set in a range
of 3-60 s.
The chart below shows the replenishment time to be set for the requested replenisher rate per m
2
-film
surface. The standard setting is 10 sec. with 500 ml replenisher rate per m
2
film surface. The replenisher
rate has to be adjusted depending on film material, chemicals and film throughput.
Relation of replenishment time and replenisher volume
Replenisher volume (ml/m2)
Replenishment time(s)
Replenishment rate
(ml per cycle)
200
4 (4)
54
300
6 (5)
81
400
8 (7)
108
500
10 (9)
135
600
13 (11)
175,5
700
15 (12)
202,5
800
17 (14)
229,5
900
19 (16)
256,5
1000
21 (18)
283,5
1100
23 (20)
310,5
1200
25 (22)
337,5
1300
27 (24)
364,5
1400
29 (26)
391,5
1500
31 (28)
418,5
1600
33 (30)
445,5
1700
35 (32)
472,5
1800
37 (34)
499,5
NOTE
Values in brackets for 60Hz power connection.
Values when pump is seat at 100% pump capacity.