2-11. RS232/422/485 (COM2) SELECTION
JP6 :
RS-232/422/485 Selection
COM1 is fixed for RS-232 function only.
COM2 is selectable for RS-232, 422, 485 function.
The jumper settings are as follows:
COM 2
Function
Jumper Settings
(pins closed)
Jumper
Illustration
RS-232
Open
RS-422
1-2, 5-6, 7-8, 9-10,
11-12,13-14,15-16,
17-18,19-20
RS-485
1-3, 4-6, 7-8, 9-10,
11-12,13-14,15-16,
17-18,19-20
*** Manufactory default --- RS-232.