3-5. WATCHDOG TIMER CONFIGURATION
This board has watchdog timer function for monitoring whether the system
is still work or not after a period of time. The user can select watchdog
timer to system reset or NMI (Non-Maskable interrupt) depending on the
jumper set in chapter 2. This is defined at I/O port
443H
. When you want to
enable the watchdog timer, please write I/O port
443H
, then the system will
either reset itself or perform the NMI function. Likewise, when you want to
disable the function, write I/O port
441H
, the system will run the command
to stop the Watchdog function.
In Prox-2622 watchdog function, you must write your program so when it
writes I/O port address 443 for enable watchdog and write I/O port address
441 for disable watchdog. The timer
'
s intervals have a tolerance of 25% so
you should program an instruction that will refresh the timer about every
second.
The following program shows you how to program the watch timer in your
program.
Watchdog enable program:
MOV
AX, 000FH
(choose the values you need; start from 0)
MOV
DX, 0443H
OUT DX,
AX
Watchdog disable program:
MOV
AX, 000FH
(this value can be ignored)
MOV
DX,
0441H
OUT
DX,
AX
The Watchdog Timer control table is as follows:
Level Value Time/sec Level Value
Time/sec
1 F 0 9 7 64
2 E 8 10 6 72
3 D 16 11 5 80
4 C 24 12 4 88
5 B 32 13 3 96
6 A 40 14 2 104
7 9 48 15 1 112
8 8 56 16 0 120
Содержание PRoX-2622
Страница 1: ...USER S MANUAL ProX 2622...
Страница 16: ...Chapter 2 Hardware Configuration Prox 2622 USER S MANUAL Page 2 5 JUMPER DIAGRAMS JUMPER SETTINGS...
Страница 39: ...Chapter 3 Software Configuration Page 3 8 Prox 2622 USER S MANUAL...
Страница 43: ...Chapter 4 Green PC Function Page 4 4 Prox 2622 USER S MANUAL...
Страница 77: ...Appendix A EXPANSION BUS Page A 6 Prox 2622 USER S MANUAL...