RLXIC-SV
♦
Intelligent Cellular
SNMP : Simple Network Management Protocol
RadioLinx Intelligent Cellular Serial Modem for the Verizon Wireless CDMA Network
User Manual
Page 90 of 146
ProSoft Technology, Inc.
May 29, 2009
10.2 SNMP
Configuration
To configure your RLXIC-SV to work as an SNMP agent, you can use either
AceManager, or a terminal connection to configure the modem using AT
commands. In AceManager, the SNMP commands are all part of the
Other
group under the
Common
group.
There are only three commands to set for SNMP in the RLXIC-SV: the listening
port, the security level, and the trap destination.
10.2.1 Listening Port
*SNMPPORT sets the port for the SNMP agent to listen on. If set to zero, default,
SNMP is disabled.
Tip:
SNMP generally uses port 161, however most Internet providers (including cellular) block all
ports below 1024 as a security measure. You should be able to use a higher numbered port such
as 10161.
10.2.2 Security Level
*SNMPSECLVL sets the security level and which version of SNMP
communications are used.
0
- No security required. SNMPv2c and SMNPv3 communications are
allowed.
1
- Authentication required. SNMPv3 is required to do authentication, and
SNMPv2c transmissions will be silently discarded. Authentication is
equivalent to the authNoPriv setting in SNMPv3.
2
- Authentication required, and messages are encrypted. SNMPv3 is
required to do authentication. SNMPv2c, and SNMPv3 authNoPriv
transmissions will be silently discarded. Authentication and encryption is
equivalent to the authPriv setting in SNMPv3.