RLXIC-SV
♦
Intelligent Cellular
Data Communication and Host Modes
RadioLinx Intelligent Cellular Serial Modem for the Verizon Wireless CDMA Network
User Manual
Page 62 of 146
ProSoft Technology, Inc.
May 29, 2009
Tip:
PassThru can only be exited by resetting or power-cycling the modem. This mode cannot be
entered via a remote Telnet session.
You can configure a string of AT commands to be sent to the RLXIC-SV when it
enters PassThru, and other PassThru settings.
PassThru Mode allows only specific AT commands. Some ALEOS commands
will be unavailable when the RLXIC-SV is in PassThru mode. The commands
usable also depend heavily on the modem model number (found on the label on
the top of the RLXIC-SV).
Note:
Some internal hardware requires upwards of 20 seconds before AT commands can be
entered, so be patient if there seems to be no response to AT commands.
7.2.4 Telnet
Mode
In AceManager you can configure Telnet operation.
If you need to change the port for Telnet (for example, you have the default port
blocked on your firewall), the option is on the
O
THER
tab. The default telnet port
is
2332
. You can also change the Telnet timeout, if the connection is idle, default
2
minutes.