MVI69-PDPMV1
♦
CompactLogix or MicroLogix Platform
Module Setup
PROFIBUS DPV1 Master
User Manual
ProSoft Technology, Inc.
Page 73 of 225
July 8, 2011
3.5
Downloading the Project to the Module Using CIPconnect
1
Right-click the MVI69-PDPMV1 module and choose
D
OWNLOAD FROM
PC
TO
D
EVICE
.
2
In the
Select Port
dropdown list, choose
1769-L3
X
E
. The default path
appears in the text box, as shown in the following illustration.
The
CIPconnect Path Editor
allows you to define the path between the PC and
the MVI69-PDPMV1 module.
Each row in the
CIPconnect Path Editor
corresponds to a physical rack in the
CIP path. Since bridging through multiple racks is not supported in the MVI69-
PDPMV1, only one row is needed for configuring the CIP path.