13
Technical data
WARNING!
Risk of personal injuries
Please observe the ”Supplement for modified version“ at the
end of the chapter!
It replaces and supplements the technical data!
13.1 Performance data
Type
Minimum pump capacity at maximum
back pressure
Maximum
stroke rate
Suction lift
Permissible
priming pres‐
sure, suction
side
Connector
size
bar
l/h
ml/stroke
Strokes/min
m WS
bar
Rp
32002
320
1.9
0.46
71
5
160
1/4
23004
230
4.0
0.52
129
5
115
1/4
10006
100
6.4
0.55
195
5
50
1/4
14006
140
6.1
1.42
71
4
70
1/4
10011
100
11.0
1.43
129
4
50
1/4
05016
50
16.7
1.43
195
4
25
1/4
07012
70
12.4
2.90
71
4
35
1/4
04522
45
22.5
2.91
129
4
22.5
1/4
02534
25
34.1
2.92
195
4
12.5
1/4
04022
40
22.4
5.26
71
4
20
3/8
02541
25
41.5
5.37
129
4
12.5
3/8
01264
12
64.0
5.45
195
4
6
3/8
All figures refer to water at 20 °C.
The suction lift applies to filled suction line and filled liquid end - when
installed correctly.
Only for "M - modified" design:
SBKa under 50 Hz operation
Technical data
40
Содержание Sigma / 2 Basic Type SBKa
Страница 51: ...51 ...