2.
Install the power supply cable to the pacing relay PCB - see the
figure in the chapter entitled "Overview of equipment and control
elements": Cable B, right.
CAUTION!
Warning of overload
If the current through the relay becomes too high, it
can be destroyed by heating.
–
Fit a circuit breaker.
Pacing relay terminal output data
Data
Value Unit
Maximum voltage
24 VDC
Maximum current
100 mA
Closing duration, approx.
100 ms
Service life *
50 x 10
6
(10 V,
10 mA)
Play
* at rated load
The contacts are potential-free.
The pacing relay is a N/O as standard.
Supply voltage for pacing relay PCB
Available supply vol‐
tages
Mains supply fre‐
quency
Power consumption
230 V AC (180-254 V) 50 / 60 Hz
10 mA (at 230 V, 50 Hz)
115 V AC (90-134 V)
50 / 60 Hz
15 mA (at 115 V, 60 Hz)
24 V DC (20-28 V)
-
10 mA (at 24 V DC)
Install the other units in line with their documentation.
Other units
Installation
23
Содержание Sigma / 2 Basic Type SBKa
Страница 51: ...51 ...