P_SI_0145_SW
Fig. 17: Cross-section through the liquid end
1
Dosing head
2
Piston
3
Dosing head flange
4
Flushing collar
5
Guide ring
6
Washer
16 Spring
20 V-sleeve packing
21 O-ring
23 FOI ring
24 Guide band
25 Dosing head flange screws
26 Liquid end retaining screws
27 Guide ring screws
31 Tube nozzles for leakage/flushing connector
1.
Remove the piston (2)
2.
Loosen the screws (25) of the dosing head flange (3) and remove
the dosing head flange.
3.
Loosen the screws (27) of the guide ring (5) and remove it.
4.
Remove the flushing collar (4), the V-sleeve packing (20), the
washer (6) and spring (16).
5.
Thoroughly clean the sealing area in the dosing head.
6.
Clean the piston (2), the guide sleeves (6) and the flushing collar (7)
7.
Dispose of the V-sleeve packing (20), the O-ring (21) from the
flushing collar, the FOI ring (23) and the guide band (24).
8.
Clean the other removed parts.
Now reassemble the parts using a reverse sequence of steps:
Repairing the liquid end
Repairs
33