A1913
Fig. 94: Wiper motor on the coupling
40. Place the wiper motor onto the coupling
Position the coupling and tighten the screw.
A1912
Fig. 95: Protective cover on the coupling
41. Remove the wiper motor, push the protective cover over the
coupling. Then push the wiper motor onto the coupling again
and fix the wiper motor in place.
42. Connect up all electrical connections
43. Seal the radiation chamber by screwing in the upper and
lower sealing stoppers.
44. Slowly open the shut-off valves upstream and downstream of
the radiation chamber, fill the UV radiation chamber with
water and vent the UV radiation chamber as necessary.
45. Switch the main switch on and/or connect the mains plug to
the power supply
46. Switch the UV system on
47. Assemble the UV system in reverse order.
ð
Note the information in the operating instructions.
Restart the UV system