The
[PAUSE] message appears in the status bar of the touch
panel. Once the
[PAUSE] signal has been cleared, the system runs
without further action in the operating status it was in before the
PAUSE input was activated.
10.4 Behaviour of the system when power is connected
The control (12) determines the behaviour of the system when
power is switched on. There are 2 options:
n
The system wakes up in
[STOP] operating status and, once
power has been switched on, must be manually started by
pressing the
[START] key on the touch panel, independently of
which operating status was active before the mains power was
switched off.
n
The system wakes up in the status that was active before
power was switched off or before the power failure. This means
that the system control registers the current operating status,
even in the event of a power failure. This affects:
– The pre-set control variable.
– The status of the
[STOP]/[START] key on the touch panel.
– The error status.
n
The system does not automatically start ozone generation, if,
prior to mains power being switched off:
– There was an error requiring acknowledgement.
– Ozone generation was stopped by the
[STOP] key on the
touch panel being pressed.
Otherwise ozone generation is automatically started with the pre-
set control variable as soon as power is switched on.
The system is pre-set by default to restart automatically when
power is switched on. If required, this behaviour can be changed in
the system controller.
Operating modes and settings
43