8.5 Setting the cooling water flow
The following settings need to be made when the system is run‐
ning with the cabinet door open.
n
Wait at least 5 minutes after the supply of power to the system
has been interrupted by the mains switch before touching the
components inside the cabinet.
n
Do not touch any electrical components while the system is
carrying current.
n
Before making the following settings, make sure that the high
voltage section is deactivated.
This is the case if the system is working in "Start without ozone
generation" operating mode with an ozone setting of 0%.
The cooling water flow volume is set at the filter pressure reducer
(24). The value is displayed on the touch panel. The nominal
cooling water flow is given in the "Technical data" chapter.
INFORMATION! A cooling water flow volume below the nominal
flow will result in lower ozone emissions from the system and over‐
heating of the ozone generator.
Ensure that the cooling water flow volume and temperature do not
exceed the permissible range, because the control device will oth‐
erwise switch off the system with an error message.
The cooling water must be free of bubbles.
Commissioning
34