System response: Production is switched off.
Cause: The product tank is completely filled.
System response: Production is switched off.
Cause: There is no external enable signal.
The system refreshes the brine in the anode.
System response: Production is not switched off.
The emergency stop switch was pressed.
System response: Production is fully switched off.
The brine tank cannot be filled.
System response: Production is switched off.
Causes:
n
The softener is regenerating.
The product has changed too much. Empty the product tank.
Causes:
n
The product has stood for over 48 h
8.2 Error messages
8.2.1 Vacuum system
System response: If the vacuum is under 120 mbar for too long,
the control will immediately switch off the power supply for the
membrane cell.
This also switches off production. The product flows as long as the
delay time shows (
‘Operation
è
Operating settings
è
Other settings
è
Product delay not to specification before switching off’). It flows
as "rejected product" to the drain.
If the vacuum reaches the setpoint during the delay time, the
system starts producing again and the product flows to the product
tank.
If the vacuum does not reach the setpoint during the delay time,
the system switches off completely. A reset is needed to restart.
Causes:
n
There is a leak somewhere in the pipe (join insufficiently
tight?).
n
The vacuum sensor is faulty.
n
The vent valve is not leak-tight.
n
The vacuum valve is set incorrectly.
The control tests the vacuum sensor every 5 hours. The vent valve
opens for 10 seconds to do so. During this time, the vacuum must
fall to below 48 mbar in 8 seconds. If this does not happen, the
control emits this error message.
Tank is full
No external signal
Anode refresh
Emergency stop
Softener is regenerating
Product changed
Vacuum is too low
Vacuum sensor faulty