18
Programming
SELECTING BATTERY TYPE
To select a battery type/charging profile perform the following:
1. Press and hold the SETUP/ENTER button for 5 seconds.
2. The current battery type and Voltage/Amperage displays will flash.
3. Use the and keys to select desired battery type.
4. The Volts and Amps readout will display the charge/conditioning and ready voltages
for each profile highlighted.
5. Press the SETUP/ENTER button to confirm selection, the LED will remain solid.
ADJUSTING THE CUSTOM BATTERY TYPE SELECTION
NOTE: *Damage can result from improper use of the custom setting. Any damage experienced
while using this setting is the responsibility of the user and not covered by the Professional Mariner
warranty. ALWAYS consult the battery manufacturer if you are unsure of the battery chemistry.
1. Follow above steps and select the “Custom” option
2. The Volts and Amps will display 13.6 (default at 13.6V)
3. The “Charge/Conditioning” LED will be blinking, indicating it can be changed
4. Use the and to select voltage up to 15.1.
5. Press the SETUP/ENTER button to confirm selection, the “Charge/Conditioning” LED
should be solid, the “Auto Maintain” LED should now be flashing
6. Use the and to select voltage up to 15.1.
7. Press the SETUP/ENTER button to confirm selection, the LED will remain solid
NOTE: During this process, real-time voltage and amperages will not be displayed.
SELF TEST MODE
1. Press and hold the SETUP/ENTER and the and buttons simultaneously for 5 seconds.
2. Only the “Self Test” LED will flash until the test is complete.
3. OK or Fault LED’s will be displayed, see the Troubleshooting section if the Fault LED
is illuminated.
EQUALIZATION
NOTE: This function is only recommended for flooded lead acid batteries and will only activate when
this type of battery is selected.
1. Use the and to select the Equalization LED.
2. Once selected press the and for 3 seconds.
3. The LED will remain solid, putting the unit in the equalization setting for 240 minutes.
4. Once complete, the charger will revert back to the previous setting.
POWER LEVEL ADJUSTMENT
1. Hold the and buttons simultaneously for 15 seconds
2. Volts will display “PL” for Power Level
3. Press the to adjust the amperage display from 100, 75, 50, 25% output.
4. Press the SETUP/ENTER button to confirm selection.
NOTE: If no action is taken after 15 seconds, the unit reverts to 100% power.
FACTORY RESET
To return the unit to original factory settings (Sealed 2)
1. Follow steps 1 and 2 in the Selecting Battery Type section
2. Use the and keys until no battery type or equalization LED’s are illuminated.