background image

 13

Setup and Operation 

Check List

  Verify AC connections are correct (L, N, G) and secure 

  Verify DC connections (+,–) are correct and secure 

  Verify DC protective cover is installed

  Connect shore/station power

  Turn on main AC breaker

  Turn on charger AC breaker

  Verify LED’s indicators are correct (see Setup and Operation section)

Please fully read the set up and operation section of this manual to begin using your installed and configured 

ProNauticP Series charger.

  Verify shore power/station  is connected and main AC breaker is in the ON position.

  Apply power to your ProNauticP Series charger by switching on branch circuit power. The charger 

will immediately come on with all LEDs lit while it performs  a system check. Once complete  the LED 

display will indicate the default BC (Battery Charger) operation as it enters the charging mode, DC 

voltage will increase.

LED indicators  on the charger are as follows:
Feature 

LED Color 

Function

AC power 

blue 

indicates power is applied

Auto temp control 

green 

with remote temp sensor connected

Active PFC 

green 

pfc active (see features section) 

Volts 

display system voltage 

equal to the charge in the selected profile 

Amps

display output amperage

based on state of charge

Charger output

percentage of charge

based on state of charge

Self test 

blue 

if self test was initiated 

OK

green

following successful self test

Auto Maintain 

green 

based on state of charge 

Charge 

green 

based on state of charge 

Conditioning

green

based on state of charge

  Once the batteries have reached programmed voltage, the ProNauticP will automatically switch 

to conditioning mode, then to Auto Maintain mode once programmed voltage/time is met, these 

states will be indicated by the LED’s on the charger or the optional remote.

  The Remote (if equipped) will display real-time voltage/amperage and state-of-charge information, 

detailed programming and display information can be found in the operation section.

  The ProNauticP requires no further attention. Once properly installed and programmed the 

ProNauticP is designed for years of trouble free use with minimal attention. For periodic  checks, 

see the maintenance section.

Note: In the event you change the battery chemistry please refer to the setup and operation section of this manual to 

reconfigure your charger.

Setup

NOTE: Factory Default charging  profile is Sealed 2 (13.6  VDC Conditioning, 13.2-13.6 VDC Auto Maintain)

BATTERY TYPES - A word on battery types and the ProMariner ProNauticP. As noted in the Battery 

Selection Table in the FEATURES section  of this manual, this unit can handle 7 different types 

of commonly available batteries. Batteries are a consumable component and will, at some point, 

require replacement. Different batteries are charged with dramatically different charging profiles. 

A change in battery type upon replacement will require resetting of the battery type on the 

ProNauticP Charger. Identifying the battery type (available on the battery or by contacting the battery 

manufacturer) and setting the ProNauticP Charger accordingly

Содержание ProNautic1210P

Страница 1: ...er _______________ Serial Number _______________ Date of Purchase _______________ ProMar Digital Performance Charging ProMariner Global AC Input Power Factor Corrected 100 260 VAC 50 60 Hz P R O M A R...

Страница 2: ...te Instructions 30 Unpacking and Inspection Thoroughly inspect your ProNauticP unit The package should contain the following 1 ProNauticP Charger 2 Parts package including a Owners Installation manual...

Страница 3: ...dby Battery Health Program Charger Output Volts Amps DISPLAY WAKE UP Press any key SELF TEST Hold all keys 5 seconds AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK BEFOREOPENING TURN OFF AC SUPPL...

Страница 4: ...e charge mode and voltage amperage in an easy to read format NOTE During Standby Energy Savings Mode only the Power Standby and Auto Maintain LED s will be illuminated Multiple Battery Type Charging C...

Страница 5: ...llation Failure to confirm adequate condition and proper installation to ABYC standard E 11 AC DC electrical systems on board boats may result in a dangerous condition and or premature failure of this...

Страница 6: ...POUR LE DEVOIR CONTINU PROT G CONTRE L EXPLOSION POUR UTILIZATION MARINE WARNING AVOID SERIOUS INJURY OR DEATH FROM FIRE EXPLOSION OR ELECTRICAL SHOCK Make connection in an open atmosphere free of ex...

Страница 7: ...ty of a battery or engine CAUTION To reduce the risk of injury charge only the battery types shown on the ProNauticP user interface label i e Lead acid type rechargeable batteries Flooded Sealed Flood...

Страница 8: ...31 battery chargers and inverters is offered throughout this manual to ensure a safe trouble free installation Please re read the PERSONAL PRECAUTIONS section of this manual prior to installation Thi...

Страница 9: ...use copy of E 11 and the other applicable standards CAUTION If you are replacing an existing battery charger please disconnect the battery charger output cables from the existing charger AND the batt...

Страница 10: ...mmon Breaker sizes are 5 10 15 20 amp for example if charger is listed below as 6 Amp at 120 230 VAC please use a 10 amp breaker AC Breaker Sizing Charger Model 110 120 volt breaker 220 250 volt break...

Страница 11: ...ductor to and from power source Wire length 10 15 20 25 30 AWG 14 12 10 10 10 12 Volt 15 Amp Wire length 10 15 20 25 30 AWG 12 10 10 8 8 12 Volt 20 Amp Wire length 10 15 20 25 30 AWG 10 10 8 6 6 12 Vo...

Страница 12: ...oats bonding system as well as the bus bar or terminal stud mentioned above This conductor is permitted to be one size smaller than the DC positive conductor chosen above in the case of a DC to the ca...

Страница 13: ...applied or when the Self Test function is initiated the numerical displays will first display 888 to indicate all segments of the displays are working and then the display will indicate either bc Batt...

Страница 14: ...n based on state of charge Conditioning green based on state of charge Once the batteries have reached programmed voltage the ProNauticP will automatically switch to conditioning mode then to Auto Mai...

Страница 15: ...tional capped and vented lead acid type batteries and will only operate when those types of batteries are selected and the user initiates the feature This process uses high voltage over a short period...

Страница 16: ...ations such as over voltage and high temperatures See the Troubleshooting section of this manual for more details in the event this occurs Optional Remote Display Optional Remote Power LED blue indica...

Страница 17: ...UVRIRLABOITE COUPERLECOURANT NEPASEXPOSERAUXINTEMP RIES ELECTRICAL BURN AND SPARK HAZARD BEFORE OPENING DISCONNECT CHARGER CONNECTIONS AT BATTERIES DANGERDEBRULURESELECTRIQUEETETINCELLES AVANTD OUVRIR...

Страница 18: ...Conservation Mode When charger has properly charged and conditioned the batteries it will enter its Auto Maintain Energy Conservation Mode In this Mode the charger will monitor and Auto Maintain the b...

Страница 19: ...and to select voltage up to 15 1 7 Press the SETUP ENTER button to confirm selection the LED will remain solid NOTE During this process real time voltage and amperages will not be displayed SELF TEST...

Страница 20: ...tain 3 Battery Type Selection Displays selected battery type 4 Time to Absorption Displays time left in Absorption mode 5 Run time Displays units total run time 6 Power Level Displays current power le...

Страница 21: ...y DC Volts High Red Indicates a high DC voltage from an outside source such as a failed alternator Using a multi meter check alternator s output generally over 15VDC Determine if fault exists in regul...

Страница 22: ...ollected on the fan shroud or items have been improperly stored around the ProNauticP Check battery terminal connections both at battery and the ProNauticP Charger for corrosion clean and reconnect im...

Страница 23: ...s ProNauticP 12volt 10 40 Amp and 24 volt 20 Amp Dimensions Inches mm ProNautic12 40P Power Factor Corrected Global AC Input 7 3 4 198 mm 8 1 2 215 mm 3 3 8 85 mm 3 1 2 90 mm 3 3 8 85 mm 3 1 2 90 mm 1...

Страница 24: ...s ProNauticP 12 volt 50 60 Amp and 24 volt 30 Amp Dimensions Inches mm ProNautic12 60P Power Factor Corrected Global AC Input 7 3 4 198mm 8 1 2 215 mm 3 5 8 93 mm 5 1 8 130 mm 3 5 8 93 mm 31 2 90 mm 1...

Страница 25: ...24 Dimensions Optional Remote Dimensions Inches mm 1 2 13 mm 2 1 2 62 mm 3 1 2 90 mm 3 1 2 90 mm...

Страница 26: ...alcium Custom Reverse Polarity DC Volts Low DC Volts High Charger High Temp Check Fan Digital ProMar Performance Charging 1 2 3 AVOIDSERIOUSINJURYORDEATHFROMELECTRICALSHOCK BEFOREOPENING TURN OFF AC S...

Страница 27: ...TENSION WARNING LOW VOLTAGE ATTENTION BASSE TENSION Preset 1 Preset 2 Flooded Sealed AGM GEL LiFePO4 Lithium Calcium Custom Reverse Polarity DC Volts Low DC Volts High Charger High Temp Check Fan Dig...

Страница 28: ...Volts High Charger High Temp Check Fan Digital ProMar Performance Charging 1 2 3 AVOIDSERIOUSINJURYORDEATHFROMELECTRICALSHOCK BEFOREOPENING TURN OFF AC SUPPLY POWER DO NOT EXPOSE TO RAIN OR SPRAY CHOC...

Страница 29: ...Board Battery Charger Typical Battery Capacity by Model Part No Model Recommended for Sealed or Flooded Lead Batteries Total AH Rating 63110 1210 65 to 100 AH 63115 1215 85 to 150 AH 63120 1220 100 t...

Отзывы: