background image

 1

Table of Contents 

Introduction... 2-3
CAUTIONS, WARNINGS AND SAFETY INSTRUCTIONS…  

4-8

Installation... 9-12
Setup and Operation…  

13-17

Programming... 18-19
Troubleshooting...  

20

Maintenance... 21
Dimensions... 22-24
Typical Wiring Configuration...  

25-27

Typical Battery Capacity...  

28

Warranty Information...  

29

Multi-Language Remote Instructions...  

30

Unpacking and Inspection:

Thoroughly inspect your ProNauticP unit. The package should contain the following:
1) ProNauticP Charger
2) Parts package including:

a. Owners/Installation manual 
b. Warranty Card
c. Temperature Probe

DAMAGE – If any parts are missing or damaged, or the unit has been damaged in 

shipping contact ProMariner Customer Service at 1-800-824-0524,  please do not 

take it back to place of purchase.

DO NOT attempt  to install or operate the unit if it has been damaged in any way.

Содержание ProNautic1210P

Страница 1: ...er _______________ Serial Number _______________ Date of Purchase _______________ ProMar Digital Performance Charging ProMariner Global AC Input Power Factor Corrected 100 260 VAC 50 60 Hz P R O M A R...

Страница 2: ...te Instructions 30 Unpacking and Inspection Thoroughly inspect your ProNauticP unit The package should contain the following 1 ProNauticP Charger 2 Parts package including a Owners Installation manual...

Страница 3: ...dby Battery Health Program Charger Output Volts Amps DISPLAY WAKE UP Press any key SELF TEST Hold all keys 5 seconds AVOID SERIOUS INJURY OR DEATH FROM ELECTRICAL SHOCK BEFOREOPENING TURN OFF AC SUPPL...

Страница 4: ...e charge mode and voltage amperage in an easy to read format NOTE During Standby Energy Savings Mode only the Power Standby and Auto Maintain LED s will be illuminated Multiple Battery Type Charging C...

Страница 5: ...llation Failure to confirm adequate condition and proper installation to ABYC standard E 11 AC DC electrical systems on board boats may result in a dangerous condition and or premature failure of this...

Страница 6: ...POUR LE DEVOIR CONTINU PROT G CONTRE L EXPLOSION POUR UTILIZATION MARINE WARNING AVOID SERIOUS INJURY OR DEATH FROM FIRE EXPLOSION OR ELECTRICAL SHOCK Make connection in an open atmosphere free of ex...

Страница 7: ...ty of a battery or engine CAUTION To reduce the risk of injury charge only the battery types shown on the ProNauticP user interface label i e Lead acid type rechargeable batteries Flooded Sealed Flood...

Страница 8: ...31 battery chargers and inverters is offered throughout this manual to ensure a safe trouble free installation Please re read the PERSONAL PRECAUTIONS section of this manual prior to installation Thi...

Страница 9: ...use copy of E 11 and the other applicable standards CAUTION If you are replacing an existing battery charger please disconnect the battery charger output cables from the existing charger AND the batt...

Страница 10: ...mmon Breaker sizes are 5 10 15 20 amp for example if charger is listed below as 6 Amp at 120 230 VAC please use a 10 amp breaker AC Breaker Sizing Charger Model 110 120 volt breaker 220 250 volt break...

Страница 11: ...ductor to and from power source Wire length 10 15 20 25 30 AWG 14 12 10 10 10 12 Volt 15 Amp Wire length 10 15 20 25 30 AWG 12 10 10 8 8 12 Volt 20 Amp Wire length 10 15 20 25 30 AWG 10 10 8 6 6 12 Vo...

Страница 12: ...oats bonding system as well as the bus bar or terminal stud mentioned above This conductor is permitted to be one size smaller than the DC positive conductor chosen above in the case of a DC to the ca...

Страница 13: ...applied or when the Self Test function is initiated the numerical displays will first display 888 to indicate all segments of the displays are working and then the display will indicate either bc Batt...

Страница 14: ...n based on state of charge Conditioning green based on state of charge Once the batteries have reached programmed voltage the ProNauticP will automatically switch to conditioning mode then to Auto Mai...

Страница 15: ...tional capped and vented lead acid type batteries and will only operate when those types of batteries are selected and the user initiates the feature This process uses high voltage over a short period...

Страница 16: ...ations such as over voltage and high temperatures See the Troubleshooting section of this manual for more details in the event this occurs Optional Remote Display Optional Remote Power LED blue indica...

Страница 17: ...UVRIRLABOITE COUPERLECOURANT NEPASEXPOSERAUXINTEMP RIES ELECTRICAL BURN AND SPARK HAZARD BEFORE OPENING DISCONNECT CHARGER CONNECTIONS AT BATTERIES DANGERDEBRULURESELECTRIQUEETETINCELLES AVANTD OUVRIR...

Страница 18: ...Conservation Mode When charger has properly charged and conditioned the batteries it will enter its Auto Maintain Energy Conservation Mode In this Mode the charger will monitor and Auto Maintain the b...

Страница 19: ...and to select voltage up to 15 1 7 Press the SETUP ENTER button to confirm selection the LED will remain solid NOTE During this process real time voltage and amperages will not be displayed SELF TEST...

Страница 20: ...tain 3 Battery Type Selection Displays selected battery type 4 Time to Absorption Displays time left in Absorption mode 5 Run time Displays units total run time 6 Power Level Displays current power le...

Страница 21: ...y DC Volts High Red Indicates a high DC voltage from an outside source such as a failed alternator Using a multi meter check alternator s output generally over 15VDC Determine if fault exists in regul...

Страница 22: ...ollected on the fan shroud or items have been improperly stored around the ProNauticP Check battery terminal connections both at battery and the ProNauticP Charger for corrosion clean and reconnect im...

Страница 23: ...s ProNauticP 12volt 10 40 Amp and 24 volt 20 Amp Dimensions Inches mm ProNautic12 40P Power Factor Corrected Global AC Input 7 3 4 198 mm 8 1 2 215 mm 3 3 8 85 mm 3 1 2 90 mm 3 3 8 85 mm 3 1 2 90 mm 1...

Страница 24: ...s ProNauticP 12 volt 50 60 Amp and 24 volt 30 Amp Dimensions Inches mm ProNautic12 60P Power Factor Corrected Global AC Input 7 3 4 198mm 8 1 2 215 mm 3 5 8 93 mm 5 1 8 130 mm 3 5 8 93 mm 31 2 90 mm 1...

Страница 25: ...24 Dimensions Optional Remote Dimensions Inches mm 1 2 13 mm 2 1 2 62 mm 3 1 2 90 mm 3 1 2 90 mm...

Страница 26: ...alcium Custom Reverse Polarity DC Volts Low DC Volts High Charger High Temp Check Fan Digital ProMar Performance Charging 1 2 3 AVOIDSERIOUSINJURYORDEATHFROMELECTRICALSHOCK BEFOREOPENING TURN OFF AC S...

Страница 27: ...TENSION WARNING LOW VOLTAGE ATTENTION BASSE TENSION Preset 1 Preset 2 Flooded Sealed AGM GEL LiFePO4 Lithium Calcium Custom Reverse Polarity DC Volts Low DC Volts High Charger High Temp Check Fan Dig...

Страница 28: ...Volts High Charger High Temp Check Fan Digital ProMar Performance Charging 1 2 3 AVOIDSERIOUSINJURYORDEATHFROMELECTRICALSHOCK BEFOREOPENING TURN OFF AC SUPPLY POWER DO NOT EXPOSE TO RAIN OR SPRAY CHOC...

Страница 29: ...Board Battery Charger Typical Battery Capacity by Model Part No Model Recommended for Sealed or Flooded Lead Batteries Total AH Rating 63110 1210 65 to 100 AH 63115 1215 85 to 150 AH 63120 1220 100 t...

Отзывы: