BLACKOUT
If there is a temporary power blackout in:
Stop or Beating phases, the machine restarts in Stop mode once power is restored.
Manual Heating phase, when power is restored, the machine is restarted and resumes Heating
without displaying any message, however the machine will log the “Black Out” event.
Manual cooling
o
in the cooling phase, after restoring the power supply, the machine will resume the
interrupted phase and check the TEV temperature as well as the duration of the
blackout. If the blackout lasted longer than the time given in the table, the machine
will display “Cool.Blackout.” (saving the event in the memory) to warn the user that
the product may have been altered. Otherwise, if the duration of the blackout was
shorter than the time given in the table below, no message will be displayed, however
the machine will log the “Black Out” event.
o
During storage, the machine will resume the interrupted phase and check how much
TEV diverges from its Temperature Set. If the difference is lower than the value set by
the Manufacturer, the “Black Out” event is logged and no message is displayed.
Instead, if the value is higher, the machine will display “Cool.Blackout” (saving the
event in the memory) to warn the user that the product may have been altered
During the Pasteurization cycles
o
in the heating phase, when power is restored, the machine resumes heating without
displaying any message, however saving the “Black Out” event.
o
in the cooling phase, after restoring the power supply, the machine will resume the
interrupted phase and check the TEV temperature as well as the duration of the
current blackout. If the blackout lasted longer than the time given in the table, the
machine will repeat the cycle from the beginning and display “CycleRestart-BLK”
(saving the event in the memory) to warn the user that the cycle is repeated as the
product may have been altered as a result of the blackout. Otherwise, if the duration of
the blackout was shorter than the time given in the table below, no message will be
displayed, however the machine will log the “Black Out” event.
o
During pause or storage phases, the machine will resume the interrupted phase and
check how much TEV diverges from its Temperature Set. If the difference is lower than
the value set by the Manufacturer, the “Black Out” event is logged and no message is
displayed. Instead, if the value is higher, the machine will repeat the cycle from the
beginning and display “CycleRestart-BLK” (saving the event in the memory) to warn