EMS

Electrical Management System

Complete Installation/Operating & Warranty Guide

EMS-LCHW50C

Rated at 240 Volts/50 Amps

Manufactured & Warranted

by

Progressive Industries

Sold & Serviced

by

VIP Enterprises

428 Childers Street

Suite 847

Pensacola, FL 32534

Direct 734-516-2056

[email protected]

www.viprv.com

1

Version 20101120

Содержание EMS-HW30C

Страница 1: ...ating Warranty Guide EMS LCHW50C Rated at 240 Volts 50 Amps Manufactured Warranted by Progressive Industries Sold Serviced by VIP Enterprises 428 Childers Street Suite 847 Pensacola FL 32534 Direct 734 516 2056 office viprv com www viprv com 1 Version 20101120 ...

Страница 2: ...ay be required VIP Enterprises recommends that you use qualified personnel When running extension cord s from the RV to a power source always use appropriate size cable Make sure that the cable is rated for outdoor use to reduce the risk of electrical shock The smaller the cable the higher resistance and more voltage loss plus it may result in an electrical fire Whenever servicing or installing th...

Страница 3: ...9 hertz from 60 cycles per second the EMS will shut power down and the error code will read E7 or E8 Accidental 220V Protection If 220 volts is detected when plugging into source power the EMS will not allow power to the RV and the EMS will not be hurt If this condition occurs while power is applied to the RV the EMS shuts off power instantly In either case the display will read the HHH for high v...

Страница 4: ...box Then connect Black to L1 White to L2 Red to L3 and Green to ground screw Torque down the screws to secure connections 7 The short cable coming from the junction box connects to the output T 2 in the same manner with the following exceptions A Insert the Black wire thru the current sensor with the green tape on it B Insert the Red wire thru the other current sensor Make sure that the wire color...

Страница 5: ... the EMS control box then connect Black wire to L1 White wire to L2 Red wire to L3 Green to ground screw and tighten each set screw and ground nut 9 The cable that was removed from the transfer switch connects to the output T 1 in the same manner with the following exceptions A Insert the Black wire thru the current sensor with the green tape on it B Insert the Red wire thru the other current sens...

Страница 6: ...mmend using generator power Important The display reads voltages between 78 and 260 volts Below will read LLL above will read HHH Accidental 220 Volt Protection Should this condition occur the display will read HHH instead of the voltage and the error code will read E 4 Power will shut down instantly DO NOT under any circumstances bypass the EMS otherwise severe damage to the RV will occur Error C...

Страница 7: ... 2 Look at the display if no reading is present call technical support If the display is reading information note the error code message If the EMS is reading Error 1 8 see error code chart on previous page this means the EMS is functioning fine If reading E0 read on 3 Look to see if the time delay indicator located in the bottom right number is flashing Wait out time delay When you see the indica...

Страница 8: ... Please do not try or attempt to visit our facility during business hours The company is not properly staffed or equipped to handle on site repair work All returns must go through technical support Progressive Industries 414B Airport Blvd Morrisville NC 27560 The unit should be properly packaged with the postage paid and the following information 1 Date of purchase 2 A detailed explanation of the ...