background image

Models: EMS-LCHW50C

Installation Instructions for Pedestal/Shore Power

See next page for both Pedestal and Generator Protection

1. Unplug RV from the power source and be sure the generator is off.

2. Determine a location for the EMS control box. Keep in mind the input and output.

Make sure you will be able to view the digital display.

3. Cut the RV power cord about 3¼ inches greater than the distance from the junction

box to the desired location of the EMS control box. Then carefully remove 3¼
inches of the outer insulation on the input and output cables.

4. Strip back each conductor

inch on both input/output ends.

5. Remove control box cover. Back off the six set screws from the top of contactor

(relay). Attach supplied ring terminals to

Green

input and output wires.

Note:

If you have solid ground wire(s), Do Not used ring terminals. Make eye(s)

with the solid ground wire.

6. Take your long cable, the one with the plug on it, and slide it into the input

(L-1)

side of control box. Then connect

Black

to L1,

White

to L2,

Red

to L3, and

Green

to ground screw. Torque down the screws to secure connections.

7. The short cable coming from the junction box connects to the output (T-2) in the

same manner with the following exceptions. A) Insert the Black wire thru the
current sensor with the green tape on it. B) Insert the Red wire thru the other
current sensor. Make sure that the wire colors match across the relay from each
other.

8. Double check all connections and make sure they are secure.

9. Secure cable end by tightening down strain relief’s over outer jacket. Do not over

tighten this could bite through insulation and cause a short.

10. Set time delay jumper on the circuit board. Factory setting is for 15 seconds, pull

head of jumper (J6 on circuit board by left side of display socket) to set for 136
seconds. See features section on time delay to determine which to use.

11. Insert display card, with display facing you and digits reading correctly, upright.

12. Attach control box cover with the six black machine screws provided. Input to input

side.

13. Mount the EMS control box.

14. Installation is complete. Next plug in and follow operation instructions.

4

Содержание EMS-HW30C

Страница 1: ...ating Warranty Guide EMS LCHW50C Rated at 240 Volts 50 Amps Manufactured Warranted by Progressive Industries Sold Serviced by VIP Enterprises 428 Childers Street Suite 847 Pensacola FL 32534 Direct 734 516 2056 office viprv com www viprv com 1 Version 20101120 ...

Страница 2: ...ay be required VIP Enterprises recommends that you use qualified personnel When running extension cord s from the RV to a power source always use appropriate size cable Make sure that the cable is rated for outdoor use to reduce the risk of electrical shock The smaller the cable the higher resistance and more voltage loss plus it may result in an electrical fire Whenever servicing or installing th...

Страница 3: ...9 hertz from 60 cycles per second the EMS will shut power down and the error code will read E7 or E8 Accidental 220V Protection If 220 volts is detected when plugging into source power the EMS will not allow power to the RV and the EMS will not be hurt If this condition occurs while power is applied to the RV the EMS shuts off power instantly In either case the display will read the HHH for high v...

Страница 4: ...box Then connect Black to L1 White to L2 Red to L3 and Green to ground screw Torque down the screws to secure connections 7 The short cable coming from the junction box connects to the output T 2 in the same manner with the following exceptions A Insert the Black wire thru the current sensor with the green tape on it B Insert the Red wire thru the other current sensor Make sure that the wire color...

Страница 5: ... the EMS control box then connect Black wire to L1 White wire to L2 Red wire to L3 Green to ground screw and tighten each set screw and ground nut 9 The cable that was removed from the transfer switch connects to the output T 1 in the same manner with the following exceptions A Insert the Black wire thru the current sensor with the green tape on it B Insert the Red wire thru the other current sens...

Страница 6: ...mmend using generator power Important The display reads voltages between 78 and 260 volts Below will read LLL above will read HHH Accidental 220 Volt Protection Should this condition occur the display will read HHH instead of the voltage and the error code will read E 4 Power will shut down instantly DO NOT under any circumstances bypass the EMS otherwise severe damage to the RV will occur Error C...

Страница 7: ... 2 Look at the display if no reading is present call technical support If the display is reading information note the error code message If the EMS is reading Error 1 8 see error code chart on previous page this means the EMS is functioning fine If reading E0 read on 3 Look to see if the time delay indicator located in the bottom right number is flashing Wait out time delay When you see the indica...

Страница 8: ... Please do not try or attempt to visit our facility during business hours The company is not properly staffed or equipped to handle on site repair work All returns must go through technical support Progressive Industries 414B Airport Blvd Morrisville NC 27560 The unit should be properly packaged with the postage paid and the following information 1 Date of purchase 2 A detailed explanation of the ...