7.4. CONSULTATION
The work of the controller can be reached with the
VIEW key.
Pressing the VIEW key several times, different mes-
sages and data will appear on the screen.
In the first touches of the VIEW key, messages
about different anomalies which the unit has suffered
might appear (this will be seen later).
If the controller has not suffered any anomalies, it
will show the data of the work being carried out at that
moment.
In the first consult screen the clock will appear, to-
gether with the state of the 5 inputs, the irrigation sectors
and the general outlets.
We have to take into account that every input has a
function assigned in the “parameters” section.
If the filter cleaning is being carried out, the fertilizer
(if there is one) is stopped temporarily and the unit will
not accept either temporary nor general malfunctions.
If there is a sector being irrigated, pressing “VIEW”
again will make another screen appear with detailed
information of every sector.
If there are more than two sectors being irrigated,
the 3
rd
and 4
th
will appear on the screen after pressing
“VIEW” again.
Pressing “VIEW” again, the unit will start the con-
sultation cycle again.
Mon.18:20 I..34.
02 03 F
1
F
3
m C1
Activated sectors
Input state:
. = deactivated, nº = activated
Day of week, hour and
minute of the clock
General outlet state
F
1
/ F
2
/F
3
/F
4
=
activated fertilizer
. = Fertilizer pending
(preirrigation, separation)
m = Fertilizer mixer running
C1 = cleaning of filter nº
“Manual”=manual activation of outlets
“COND. STOP”=conditional stop
S02
P14 F1
0:08 F2
0:19
I=01:58
F3 0:21 F4 0:15
For every two activated sec-
tors, a screen with their
valves will be displayed.
In the first line shows the sector nº, program
nº with the values of the F1 / F2 units left, and
in the second line the irrigation time left and
the F3 / F4 units left.
7.4.1. Anomalies
On pressing the “VIEW” key, if there are any
anomalies, the first will be shown on the screen, if not, it
will go to general consultation (7.4.).
On having an anomaly on the screen and pressing
“VIEW”, the unit will ask if we want to erase it. Answer
yes or no.
Erase previous
anomaly (Yes/No) ?
Up to ten screens with recorded anomalies may
appear. If there are more than 10, the last one would
always remain recorded on the tenth screen.
The anomalies that the unit can store in its memory
are:
- POWER SUPPLY FAILURE.
- TEMPORARY MALFUNCTION.
- FERTILIZER LEFT OVER.
- PROGRAM DOES NOT ENTER.
- FERTILIZER DOES NOT ENTER.
- INTERFERENCE.
The unit records power cuts superior to a minute
and
inferior
to
24
hours.
The
following
screen
informs
that there was a cut in the power supply from 12:57 on
Monday to 2:45 on Tuesday.
* Power cut *
Mon.12:57- -Tu.02:45
Every time a program finishes through the input of
temporary malfunction, a recording takes place. This
anomaly indicates a stop for temporary malfunction at
23:45 on Monday, canceling the irrigation of program
n.3.
*Temporary malfunction*
Mon.23:45 P03
If at the end of the irrigation program there is fertil-
izer left over, the following anomaly will be shown, indi-
cating the program and the fertilizer units left.
*Fertilizer left*
P02 F
1
0:02 F
2
0:34
The following screen informs that program n.14
can not enter as there are already 8 sectors working
simultaneously (the limit of the number of sectors that
Содержание Agronic 2000 Series