18
•
P
RO
-8
A
• OFF: No ready signal. This setting also disables the sound indicating
that a switch is pressed or a control is turned.
• DIM: The modeling light will be turned off when the generator is
being charged, and turned on again when the charging is completed.
This setting also disables the sound indicating that a switch is pressed
or a control is turned.
• BEEP: A clear ”beep” will sound to indicate that the charging of the
generator is completed. This setting also enables the sound indicating
that a switch is pressed or a control is turned.
• BEEP-DIM: The modeling light will be turned off when the genera-
tor is being charged, and turned on again when the charging is com-
pleted. A clear ”beep” will also sound to indicate that the charging
is completed. This setting also enables the sound indicating that a
switch is pressed or a control is turned.
Speed control
The versatile recycling speed settings make it possible to effi ciently uti-
lize the mains power supply by adjusting and optimizing the maximum
possible speed and load without blowing fuses. The generator’s amper-
age load from the mains power supply corresponds proportionally to the
speed setting.
18