Seite 26
•
Start the application procedure by tapping the „draw“ button. When using a
gap applicator this can be eithe
r in “Single”
mode or in „Reverse“
mode.
•
Remove and clean the gap applicator.
•
If working in “Single” mode, return the drawing unit (23) to the start position by
tapping the
on the touch screen.
In „Reverse“ mode
the drawing
unit (23) returns to the start position automatically.
•
Remove your substrate. If the device is not needed for further applications,
switch it off with the main switch (10).
For substrates between 4 mm and 11 mm thickness, use the
included weight lifter. To install, remove the weight (7) and
place the weight lifter in the holding device (8) with the top
marker facing up, then place the weight (7) back in the holding device (8).
If the weight (7) has to be lifted even higher, place the weight lifter with the top
marker facing down in the holding device (8). The resulting height difference can be
seen below:
7
Operation and Menu
7.1 Main screen
The Proceq ZAA 2600 is equipped with a capacitive touch screen with a glass front.
The touch screen is configured to allow operation with gloves up to 1 mm thickness.