6
© 2014 Proceq SA
2. technical Specifications
Pundit PL-200
Pundit PL-200PE
Range
0.1 – 7930 μs
Resolution
0.1 μs (< 793 μs), 1 μs (> 793 μs)
Display
7” colour display 800x480 pixels
Pulse Voltage UPV
100 – 450 Vpp
UPE
–
100 – 400 Vpp
Bandwidth
20 – 500 kHz
Receiver Gain
1x – 10’000x (0 – 80dB) [11 steps]
Memory
Internal 8 GB Flash memory
Regional Settings
Metric and imperial units and multi-language
supported
Battery
Lithium Polymer, 3.6 V, 14.0 Ah
Battery Lifetime
> 8h (in standard operating mode)
Operating
Temperature
0°C – 30°C (Charging, running instrument)
0°C – 40°C (Charging, instrument is off)
-10°C – 50°C (Non-charging)
Humidity
< 95 % RH, non condensing
IP Classification
IP54
Pulse Echo Range
0.1 – 1200 μs
Transducer
Frequency
50 kHz
Aperture Size
2x25 cm
2
3. Operation
The information provided in this manual covers the Pulse Echo application
only. The Pundit PL-200PE also supports all functionality provided by the
Pundit PL-200. It is necessary to purchase the BNC adapter cable (Part
No. 327 01 049) for operation with standard P-wave transducers. A full
listing of the standard transducers can be found on the Proceq website.
The Pundit PL-200 operating manual is provided on the product DVD.
3.1 Getting Started
Battery installation
To install the Battery (B) into the Pundit Touchscreen (A), lift the stand as
shown. Insert the battery and fasten in place with the screw.
There are three status LEDs
1
(see page page 3). The middle LED is
red while charging and turns to green when fully charged. The other LEDs
are application specific.
NOTE! Only use the battery charger provided.