background image

14 

© 2014 Proceq SA

5.3  Accessories

PART NO.

 

DESCRIPTION

327 01 043

Carrying strap complete

325 40 150

Transducer holder complete

327 01 049

BNC adapter cable for Pundit PL-200

325 40 021

Cable with BNC-plug, 1.5 m (5 ft)

325 40 022

Cable with BNC-plug, 10 m (33 ft)

710 10 031

Ultrasound couplant, 250 ml

325 40 048

Shear wave couplant, 100 g

327 01 033

Battery complete

327 01 053

Quick charger

710 10 028

Calibration rod 25 μs for Pundit PL-200

710 10 029

Calibration rod 100 μs for Pundit PL-200

327 01 070

Snap Ferrite for BNC Adapter cable*

327 01 051

Pundit Pulse Echo Cable

327 00 027

Pundit Pulse Echo Contact Tester complete

327 20 002

Pundit PL-200PE UPV Kit including BNC adapter cable, 

2x cable with BNC-plug, L=1.5m (5ft), Ultrasound coup-

lant, 250ml bottle, 2 transducers 54 kHz, calibration rod

327 01 071S

Calibrated Tape (Set of 5)

 

* In the case that receiving equipment within a radius of 10m suffers from interfer-

ence, it is possible to order a ferrite to fit onto the BNC adapter cable. This serves 

to further reduce the electromagnetic radiation produced by the instrument.

6.  Maintenance and Support

6.1  Maintenance

To guarantee consistent, reliable and accurate measurements, the instru-
ment should be calibrated on a yearly basis. The customer may however, 
determine the service interval based on his or her own experience and 
usage.

6.2  Support  Concept

Proceq is committed to providing a complete support service for 
this instrument by means of our global service and support fa-
cilities. It is recommended that the user register the product on 
www.proceq.com to obtain the latest on available updates.

6.3  Warranty information

Each instrument is backed by the standard Proceq warranty and extend-
ed warranty options.
• 

Electronic portion of the instrument: 24 months

• 

Mechanical portion of the instrument: 6 months

6.4  disposal

Disposal of electric appliances together with household waste is not 
permissible. In observance of European Directives 2002/96/EC, 
2006/66/EC and 2012/19/EC on waste, electrical and electronic equip-
ment and its implementation, in accordance with national law, electric 
tools and batteries that have reached the end of their life must be col-
lected separately and returned to an environmentally compatible recy-
cling facility.

Содержание Pundit PL-200PE

Страница 1: ...Made in Switzerland 60 Years of Innovation Pundit PL 200PE OPERATING INSTRUCTIONS Made in Switzerland 60 Years of Innovation...

Страница 2: ...ucer D Pundit Pulse Echo Cable E Pundit Pulse Echo Contact Tester F Battery Charger G USB Cable H DVD with Software I Documentation J Carrying Strap K Calibrated Tape Part of the Pundit Pulse Echo Tra...

Страница 3: ...9 9 9 9 9 9 9 9 9 9 23 2 3 9 3 2 23 3 2014 Proceq SA Overview Pundit PL 200PE 1 1 2 3 4 5 6 7 8 9 10 2...

Страница 4: ...3 5 Measurement Modes 11 3 6 Measuring with Pundit PL 200PE 12 4 Explorer 12 4 1 Analysis of B Scans 13 5 Ordering Information 13 5 1 Units 13 5 2 Transducers 13 5 3 Accessories 14 6 Maintenance and S...

Страница 5: ...ents Serious damage resulting from the effects of foreign bodies accidents vandalism and force majeure All information contained in this documentation is presented in good faith and believed to be cor...

Страница 6: ...Transducer Frequency 50 kHz Aperture Size 2x25 cm2 3 Operation The information provided in this manual covers the Pulse Echo application only The Pundit PL 200PE also supports all functionality provi...

Страница 7: ...ain menu is displayed All functions may be accessed directly via the touchscreen Return to the previous menu by pressing the back button or the return icon arrow at the top left of the touchscreen Mea...

Страница 8: ...a quick read out of slab thickness is desired For complex objects containing internal defects pipes and rebars it is recommended to perform a complete B Scan for analysis of the object Filter Filters...

Страница 9: ...g a measurement Zoom out by placing thumb and index finger apart on the screen and pinching them together Pan Pan the image from left to right by dragging Measuring screen controls see page 3 1 Filena...

Страница 10: ...ows a marker to be set on a second echo and the difference between thet two echos is displayed Manually adjust the colour intensity 10 Automatic Estimation of Pulse Velocity This setting is available...

Страница 11: ...on the transducer The LED s on the transducer provide a visual feedback when a meas urement has taken place successfully This is accompanied by an acoustic tone on the display device The volume of th...

Страница 12: ...er 3 4 Physical influences on the Measurement Inhomogeneities e g aggregate particles voids in concrete influence the propagation of an ultrasound pulse They will scatter the signal The effect is very...

Страница 13: ...ink once the files have been downloaded to a PC 5 Ordering Information 5 1 Units PART NO DESCRIPTION 327 10 002 Pundit Touchscreen without transducers Consisting of Pundit Touchscreen BNC adapter cabl...

Страница 14: ...ectromagnetic radiation produced by the instrument 6 Maintenance and Support 6 1 Maintenance To guarantee consistent reliable and accurate measurements the instru ment should be calibrated on a yearly...

Страница 15: ...ct the language and the date and time format to be used Connecting to a Pundit Touchscreen Unit Connect the Pundit Touchscreen Unit to a USB port then select the fol lowing icon to download data from...

Страница 16: ...n each case a drop down selection box will appear with the choice of setting 7 4 Analysis of B Scans PL Link provides a number of tools that assist in the analysis of B Scans Zoom into the B Scan usin...

Страница 17: ...he various export options to be chosen In both cases the preview window shows the effects of the current out put selection Finish by clicking on export to select the file location name the file and in...

Страница 18: ...Industrial Road 02 02A Morningstar Centre Singapore 536202 Phone 65 6382 3966 Fax 65 6382 3307 info asia proceq com Proceq Rus LLC Ul Optikov 4 korp 2 lit A Office 410 197374 St Petersburg Russia Phon...

Отзывы: