4.1  Analysis of B-Scans

Please refer to the separate booklet Pundit PL-200PE B-Scan Measure-
ment Examples.

Explorer provides a number of tools that assist in the analysis of B-Scans.
•  Drag the cross hairs to a point of interest. (e. g. back wall of sample 

as shown here)

•  The object thickness (e. g. 0.3m) is displayed on the y-axis.
•  The object position from the beginning of the scan is displayed on the 

x-axis.

•  The current A-Scan (e. g. #22) is indicated above the B-Scan and also 

in the the A-Scan window.

•  The current transmission time is displayed at the right hand side of the 

of the screen.

•  The cursor position may also be adjusted by dragging on the position 

display boxes.

•  SAFT and Envelope may be switched ON/OFF in Settings.
•  Pulse velocity may be corrected.
•  Spacing between measurements may be corrected.
•  The color scheme may be adjusted.
•  Any modifications made to the scan may be saved.
•  All of these items may be adjusted later in PL-Link once the files have 

been downloaded to a PC.

5.  Ordering information

5.1  units

PART NO. 

DESCRIPTION

327 10 002

Pundit Touchscreen 

without transducers 

Consisting of: Pundit Touchscreen, BNC adapter cable, 

battery charger, USB cable, DVD with software, docu-

mentation, carrying strap and carrying case

327 10 001

Pundit PL-200

  

Consisting of: Pundit Touchscreen, 2 Transducers 54 kHz, 

2 BNC cables 1.5 m, couplant, calibration rod, BNC 

adapter cable, battery charger, USB cable, DVD with soft-

ware, documentation, carrying strap and carrying case

327 20 001

Pundit PL-200PE 

 

Consisting of: Pundit Touchscreen, Pundit Pulse Echo 

Transducer incl. cable, contact tester, battery charger, 

USB cable, calibrated tape, DVD with software, docu-

mentation, carrying straps and carrying case

5.2  transducers

PART NO.

 

DESCRIPTION

325 40 026S

2 Transducers 24 kHz

325 40 131S

2 Transducers 54 kHz

325 40 141S

2 Transducers 150 kHz

325 40 177S

2 Transducers 250 kHz

325 40 175S

2 Transducers 500 kHz

325 40 176

2 Exponential Transducers 54 kHz, incl. calibration rod

325 40 049

2 S-Wave Transducers 250 kHz, incl. couplant

327 40 130

Pulse Echo Transducer, incl. cable and contact tester

Содержание Pundit PL-200PE

Страница 1: ...Made in Switzerland 60 Years of Innovation Pundit PL 200PE OPERATING INSTRUCTIONS Made in Switzerland 60 Years of Innovation...

Страница 2: ...ucer D Pundit Pulse Echo Cable E Pundit Pulse Echo Contact Tester F Battery Charger G USB Cable H DVD with Software I Documentation J Carrying Strap K Calibrated Tape Part of the Pundit Pulse Echo Tra...

Страница 3: ...9 9 9 9 9 9 9 9 9 9 23 2 3 9 3 2 23 3 2014 Proceq SA Overview Pundit PL 200PE 1 1 2 3 4 5 6 7 8 9 10 2...

Страница 4: ...3 5 Measurement Modes 11 3 6 Measuring with Pundit PL 200PE 12 4 Explorer 12 4 1 Analysis of B Scans 13 5 Ordering Information 13 5 1 Units 13 5 2 Transducers 13 5 3 Accessories 14 6 Maintenance and S...

Страница 5: ...ents Serious damage resulting from the effects of foreign bodies accidents vandalism and force majeure All information contained in this documentation is presented in good faith and believed to be cor...

Страница 6: ...Transducer Frequency 50 kHz Aperture Size 2x25 cm2 3 Operation The information provided in this manual covers the Pulse Echo application only The Pundit PL 200PE also supports all functionality provi...

Страница 7: ...ain menu is displayed All functions may be accessed directly via the touchscreen Return to the previous menu by pressing the back button or the return icon arrow at the top left of the touchscreen Mea...

Страница 8: ...a quick read out of slab thickness is desired For complex objects containing internal defects pipes and rebars it is recommended to perform a complete B Scan for analysis of the object Filter Filters...

Страница 9: ...g a measurement Zoom out by placing thumb and index finger apart on the screen and pinching them together Pan Pan the image from left to right by dragging Measuring screen controls see page 3 1 Filena...

Страница 10: ...ows a marker to be set on a second echo and the difference between thet two echos is displayed Manually adjust the colour intensity 10 Automatic Estimation of Pulse Velocity This setting is available...

Страница 11: ...on the transducer The LED s on the transducer provide a visual feedback when a meas urement has taken place successfully This is accompanied by an acoustic tone on the display device The volume of th...

Страница 12: ...er 3 4 Physical influences on the Measurement Inhomogeneities e g aggregate particles voids in concrete influence the propagation of an ultrasound pulse They will scatter the signal The effect is very...

Страница 13: ...ink once the files have been downloaded to a PC 5 Ordering Information 5 1 Units PART NO DESCRIPTION 327 10 002 Pundit Touchscreen without transducers Consisting of Pundit Touchscreen BNC adapter cabl...

Страница 14: ...ectromagnetic radiation produced by the instrument 6 Maintenance and Support 6 1 Maintenance To guarantee consistent reliable and accurate measurements the instru ment should be calibrated on a yearly...

Страница 15: ...ct the language and the date and time format to be used Connecting to a Pundit Touchscreen Unit Connect the Pundit Touchscreen Unit to a USB port then select the fol lowing icon to download data from...

Страница 16: ...n each case a drop down selection box will appear with the choice of setting 7 4 Analysis of B Scans PL Link provides a number of tools that assist in the analysis of B Scans Zoom into the B Scan usin...

Страница 17: ...he various export options to be chosen In both cases the preview window shows the effects of the current out put selection Finish by clicking on export to select the file location name the file and in...

Страница 18: ...Industrial Road 02 02A Morningstar Centre Singapore 536202 Phone 65 6382 3966 Fax 65 6382 3307 info asia proceq com Proceq Rus LLC Ul Optikov 4 korp 2 lit A Office 410 197374 St Petersburg Russia Phon...

Отзывы: