•  A complete charge requires <9h (Instrument not operating).
•  Charging time is much longer if the instrument is in use.
•  An optional quick charger (Part No. 327 01 053) can be used to charge 

a spare battery outside of the instrument. In this case it takes <4h for 
a complete charge.

Energy Saving

Energy saving, time to dim display and time to turn off display, may be 
programmed as desired under System/Power settings. 

Connecting the transducer

(D)

Connect the Pulse Echo Transducer (C) to the Pundit Touchscreen (A) 
using the Pulse Echo Cable (D).

Buttons 

Lift the protective visor.
The upper right of the screen there are three buttons 

2

 (see page 3).

Power On/Off – Press to power on. Press and hold to power off.

Soft Key – Switches in and out of full screen view.

Back Button – Returns to previous screen.

3.2  Main Menu

On start up the main menu is displayed. All functions may be accessed 
directly via the touchscreen. Return to the previous menu by pressing the 
back button or the return icon (arrow) at the top left of the touchscreen.

Measurement: 

Application specific measurement screen. 

Settings:

For application specific settings.

Explorer: 

File manager functionality for reviewing measure-

ments saved on the instrument.

System:

For system settings, eg. language, display options, 

power saving

Information:

For device information.

Exit:

Power Off. 

3.3  Settings

Scroll up and down the screen by dragging your finger up or down the 
screen. The current setting is displayed on the right hand side. Tap on an 
item to adjust it.

transducer

Connected Transducer

If a Pulse Echo Transducer is connected this will be recognized automati-
cally.

Test Transducer

Each individual dry contact transducer can be tested for correct func-
tionality.
The graphic on the right hand side of the screen indicates which trans-
ducer pair is to be tested (blue highlight). Press the Pulse Echo Contact 

Содержание Pundit PL-200PE

Страница 1: ...Made in Switzerland 60 Years of Innovation Pundit PL 200PE OPERATING INSTRUCTIONS Made in Switzerland 60 Years of Innovation...

Страница 2: ...ucer D Pundit Pulse Echo Cable E Pundit Pulse Echo Contact Tester F Battery Charger G USB Cable H DVD with Software I Documentation J Carrying Strap K Calibrated Tape Part of the Pundit Pulse Echo Tra...

Страница 3: ...9 9 9 9 9 9 9 9 9 9 23 2 3 9 3 2 23 3 2014 Proceq SA Overview Pundit PL 200PE 1 1 2 3 4 5 6 7 8 9 10 2...

Страница 4: ...3 5 Measurement Modes 11 3 6 Measuring with Pundit PL 200PE 12 4 Explorer 12 4 1 Analysis of B Scans 13 5 Ordering Information 13 5 1 Units 13 5 2 Transducers 13 5 3 Accessories 14 6 Maintenance and S...

Страница 5: ...ents Serious damage resulting from the effects of foreign bodies accidents vandalism and force majeure All information contained in this documentation is presented in good faith and believed to be cor...

Страница 6: ...Transducer Frequency 50 kHz Aperture Size 2x25 cm2 3 Operation The information provided in this manual covers the Pulse Echo application only The Pundit PL 200PE also supports all functionality provi...

Страница 7: ...ain menu is displayed All functions may be accessed directly via the touchscreen Return to the previous menu by pressing the back button or the return icon arrow at the top left of the touchscreen Mea...

Страница 8: ...a quick read out of slab thickness is desired For complex objects containing internal defects pipes and rebars it is recommended to perform a complete B Scan for analysis of the object Filter Filters...

Страница 9: ...g a measurement Zoom out by placing thumb and index finger apart on the screen and pinching them together Pan Pan the image from left to right by dragging Measuring screen controls see page 3 1 Filena...

Страница 10: ...ows a marker to be set on a second echo and the difference between thet two echos is displayed Manually adjust the colour intensity 10 Automatic Estimation of Pulse Velocity This setting is available...

Страница 11: ...on the transducer The LED s on the transducer provide a visual feedback when a meas urement has taken place successfully This is accompanied by an acoustic tone on the display device The volume of th...

Страница 12: ...er 3 4 Physical influences on the Measurement Inhomogeneities e g aggregate particles voids in concrete influence the propagation of an ultrasound pulse They will scatter the signal The effect is very...

Страница 13: ...ink once the files have been downloaded to a PC 5 Ordering Information 5 1 Units PART NO DESCRIPTION 327 10 002 Pundit Touchscreen without transducers Consisting of Pundit Touchscreen BNC adapter cabl...

Страница 14: ...ectromagnetic radiation produced by the instrument 6 Maintenance and Support 6 1 Maintenance To guarantee consistent reliable and accurate measurements the instru ment should be calibrated on a yearly...

Страница 15: ...ct the language and the date and time format to be used Connecting to a Pundit Touchscreen Unit Connect the Pundit Touchscreen Unit to a USB port then select the fol lowing icon to download data from...

Страница 16: ...n each case a drop down selection box will appear with the choice of setting 7 4 Analysis of B Scans PL Link provides a number of tools that assist in the analysis of B Scans Zoom into the B Scan usin...

Страница 17: ...he various export options to be chosen In both cases the preview window shows the effects of the current out put selection Finish by clicking on export to select the file location name the file and in...

Страница 18: ...Industrial Road 02 02A Morningstar Centre Singapore 536202 Phone 65 6382 3966 Fax 65 6382 3307 info asia proceq com Proceq Rus LLC Ul Optikov 4 korp 2 lit A Office 410 197374 St Petersburg Russia Phon...

Отзывы: