6
© 2014 Proceq SA
Operation - Power ON / OFF
• Power ON - Press the power button.
• Power OFF - It is only possible to power off from the main menu screen. If you are in any other
menu, press the back button to return to the main menu.
Press the power button once for the information screen showing the serial number, hardware
and firmware versions and the battery status:
Press the power button again to power off.
• Return to the main menu from the information screen by pressing the center key or the back button.
The instrument shuts down automatically after 5 minutes of inactivity.
3.3 The Proceq DY-2 Menu
On start-up the main menu screen will be shown.
Set Measurement
Unit
Start Test
Memory
Select Test Disc
Diameter / Set Test
Disc Area
Set Load Rate
/ Set Maximum
Load
Set Date and Time
4. Test Parameter Settings
Note: The most current test settings are saved when the unit is powered off.
Setting the Units
• Choose between: lbf, kN, psi, N/mm2 and MPa.
• Press the center key to complete the action.
Note: Once the unit has been selected, the load rate selection will be defined in the same
unit. Load rate and disc size settings remain the same when switching from one unit to
another. The unit is converted automatically, e.g. 50 mm = 1.97”, 0.2 MPa/s = 29 psi/s